background image

Содержание KESS907SBL05

Страница 1: ...ION INSTRUCTIONS 30 76 2 CM FREESTANDING AND SLIDE IN ELECTRIC RANGES INSTRUCTIONS D INSTALLATION DE CUISINII_RES l_LECTRIQUES AUTOPORTANTES OU COULISSANTES DE 30 76 2 CM Table of Contents Table des matieres 2 J j_ W102461190 ...

Страница 2: ...lomb de la cuisiniere 23 Achever I installation 23 Deplacement de la cuisiniere 24 GABARIT POUR LA BRIDE ANTIBASCULEMENT 24 RANGE SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that ...

Страница 3: ...minals with upturned ends A UL listed strain relief Check local codes Check existing electrical supply See Electrical Requirements section It is recommended that all electrical connections be made by a licensed qualified electrical installer IMPORTANT Observe all governing codes and ordinances It is the installer s responsibility to comply with installation clearances specified on the model serial...

Страница 4: ... A B E A 53 4 14 6 cm B 30 76 2 cm C 413 4 106 0 cm overafl height with leveling legs screwed all the way in D 36 91 4 cm cooktop trim height with leveling legs screwed all the way in E 30 76 2 cm F 271 4 69 2 cm max from handle to standoff at back of range G Model serial number plate located on the right hand side oven door trim Range can be raised approximately 1 2 5 cm by adjusting the leveling...

Страница 5: ...o If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge is in accordance with local codes Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and...

Страница 6: ...als with upturned ends terminating in a NEMA Type 14 50P plug on the supply end The fourth grounding conductor must be identified by a green or green yellow cover and the neutral conductor by a white cover Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft 1 22 m long 4 wire receptacle 14 50R The minimum conductor sized for the copper 4 wire power cord are 40 amp c...

Страница 7: ... 3 8 1 0 cm dimension Countertop must be level Place level on countertop first side to side then front to back If countertop is not level range will not be level Range must be level for satisfactory baking conditions INSTALLATION INSTRUCTIONS A Measure at locations marked A B C D 2 Measure from the floor to the underside of the range cooktop 3 t A B C A Distance from floor to underside of range co...

Страница 8: ...t will slide under the range and onto the rear leveling leg prior to anti tip bracket installation Tip Over Hazard A child or adult can tip the range and be killed Connect anti tip bracket to rear range foot Reconnect the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults Contact a qualified floor covering install...

Страница 9: ...s Power Supply Cord Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or electrical shock Direct Wire Electrical Shock Hazard Disconnect power before servicing Use 8 gauge copper or 6 gauge aluminum wire Electricaly ground range Falure to folow these instructions can...

Страница 10: ... opening A Removable retaining nut B UL fisted strain relief A Black horizontal cross brace B Flexible conduit Tighten strain relief screw against the flexible conduit 5 Complete installation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available Electrical Connection Options If your home has And you will be Go to Section connecting to 4 ...

Страница 11: ...e 1 black wires to the outer terminal block posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement use only a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 13 8 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 8 Tighten strain relief screws 9 Replace terminal block access cover...

Страница 12: ...lack in the wire to easily attach the wiring terminal block 3 Complete electrical connection according to your type of electrical supply 4 wire or 3 wire connection 4 wire Connection Direct Wire Use this method for New branch circuit installations 1996 NEC Mobile homes Recreational vehicles In an area where local codes prohibit grounding through the neutral i A B C A Metal ground strap B Discard C...

Страница 13: ...w enough slack to easily attach the wiring to the terminal block A B 2 Attach terminal lugs to line 2 red bare green ground and line 1 black wires Loosen do not remove the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs Securely tighten setscrew to torque as shown in the following Bare Wire Torque Specifications chart A _j f j y _i _ _ _ _ _ _ ...

Страница 14: ...f there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See the Level Range section 5 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by shipping material Dry thoroughly with a soft cloth For more information read...

Страница 15: ... level For direct wired ranges Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock 1 Disconnect power 2 Using two or more people slide range onto cardboard or hardboard to perform cleaning or maintenance 3 Disconnect wiring if necessary 4 Perform cleaning or maintenance 5 Reconnect wiring i...

Страница 16: ...e basculer la cuisiniere ce qui peut causer un d_ces Joindre la bride antibasculement au pied arriere de la cuisiniere Joindre de nouveau la bride antibasculement si la cuisiniere est d6plac6e Le non respect de ces instructions peut causer un d_ces ou des brOlures graves aux enfants et aux adultes EXIGENCES D INSTALLATION Rassembler les outils et pieces necessaires avant de commencer Pi_ces fourni...

Страница 17: ...mum de 5 12 7 cm au del du bas des placards Respecter les dimensions indiquees pour les ouvertures decouper dans les placards ces dimensions constituent les valeurs minimales des degagements de separation La bride antibasculement de plancher doit etre installee Pour I installation de la bride antibasculement expediee avec la cuisiniere voir la section Installation de la bride antibasculement Une s...

Страница 18: ...porte du four sera en saillie de 1 2 5 cm au del de la base des placards de 24 61 0 cm A A 3011A6 77 6 cm B 35 90 5 cm Hauteur jusqu Dla partie inf_rieure du rebord de la table de cuisson avec les pieds de nivellement completement abaiss6s C Plaque signal_tique situ_e sur la garniture de porte du four c6t_ droit D 30 76 2 cm E 27 69 2 cm 271_ 70 3 cm sur les modeles KERS8OTXSP et KESS907XSP Longue...

Страница 19: ...ds 7 17 8 cm max partir du plancher F La porte ou charniere du placard ne doit pas d_passer I int_rieur de I ouverture Cuisini_re coulissante G A Profondeur des placards sup_rieurs 13 33 cm B Largeur min de I ouverture 30 76 2 cm C Pour le d_gagement minimal vers la partie sup_rieure de la table de cuisson voir la REMARQUE D Profondeur d ouverture 223 4 57 8 cm E Largeur min de I ouverture 30 76 2...

Страница 20: ... en chevauchement sur les extremit6s du plan de travail Si la largeur de I espace disponible est de 30 76 2 cm et si la rive avant du plan de travail est plane et I equerre aucune preparation du plan de travail ne sera necessaire Si le bord avant du plan de travail a ete realise par moulage il sera necessaire de realiser une surface plane de 3 8 1 cm dans chaque angle avant de I ouverture II peut ...

Страница 21: ...r sur le carton ou le panneau de fibres dur 2 Ajuster les pieds de nivellement a la hauteur necessaire Les pieds de nivellement peuvent _tre desserres pour ajouter une hauteur maximale de 1 2 5 cm Une Iongueur minimum de 3 le 5 mm est necessaire pour engager la bride antibasculement REMARQUE Si un ajustement de la hauteur est effectu6 alors que la cuisiniere est debout incliner la cuisiniere vers ...

Страница 22: ...tibasculement avec les trous dans le plancher Fixer la bride antibasculement avec les vis fournies Selon I epaisseur du materiau du plancher il peut _tre necessaire d employer des vis plus Iongues pour ancrer la bride dans le sous plancher Vous trouverez les vis necessaires dans votre quincaillerie locale 7 Deplacer la cuisiniere suffisamment pres de I ouverture pour pouvoir effectuer les raccorde...

Страница 23: ...usles outils 3 Jeter ou recycler tousles materiaux d emballage 4 Verifier que la cuisiniere est d aplomb Voir Reglage de I aplomb de la cuisiniere 5 Pour I elimination des residus de cire laisses par les materiaux d expedition utiliser une solution d eau tiede et de produit de nettoyage menager liquide doux Secher completement avec un chiffon doux Pour plus de renseignements voir la section Entret...

Страница 24: ... fagon ce que le pied arriere de la cuisiniere se trouve sous la bride antibasculement 6 Verifier que la cuisiniere est d aplomb Lorsqu on deplace la cuisiniere la faire glisser sur une planche de carton ou en de fibres dur pour eviter d endommager le rev6tement du sol Si le deplacement de la cuisiniere est necessaire pour le nettoyage ou I entretien ANTI TIPBRACKETTEMPLATE GABARITPOUR LA BRIDEANT...

Отзывы: