Tools needed

Phillips screwdriver

Measuring tape

Hand or electric drill (for wall cabinet installations)

1" (2.5 cm) drill bit (for wall cabinet installations)

Level

Flat-blade screwdriver

Parts needed

UL listed or CSA approved conduit connector

UL listed wire connectors

Warming Drawer Deflector Kit (for ovens installed above a 
warming drawer)

Order Part Number W10489566 for white 27" (68.6 cm) kit
Order Part Number W10489564 for black 27" (68.6 cm) kit
Order Part Number W10489568 for stainless steel 27" 
(68.6 cm) kit
Order Part Number W10489567 for white 30" (76.2 cm) kit
Order Part Number W10489565 for black 30" (76.2 cm) kit
Order Part Number W10489569 for stainless steel 30" 
(76.2 cm) kit

To order, see the “Assistance or Service” section of the Use 
and Care Guide.

Parts supplied 

#8-14 x 1" screws - single ovens (2), double ovens (4)

Two #8-18 x 

³⁄₈

" screws - bottom vent

Four #8-18 x 

¹⁄₄

" screws - bottom vent trim

Four #8-18 x 

³⁄₈

" screws - double oven feet

Bottom vent

Bottom vent trim

Two feet - double oven

Two front feet - double oven

Four grommets - single ovens (2), double ovens (4)*

Foam strip - single oven**

Check local codes. Check existing electrical supply. See 
“Electrical Requirements.”

It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.

*Grommets not required or included with models KEBK171B, 

KEBK101B, KEBK276B, KEBK206B, KEBS179B, KEBS109B, 
KEBS277B, KEBS279B, KEBS207B, KEBS209B, KEBU109B 
and KEBU209B.

**Foam strip not included with double oven.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. 

Cabinet opening dimensions that are shown must be used. 
Given dimensions provide minimum clearance with oven.

Recessed installation area must provide complete enclosure 
around the recessed portion of the oven. 

Grounded electrical supply is required. See “Electrical 
Requirements” section.

Electrical supply junction box should be located 3" (7.6 cm) 
maximum below the support surface when the oven is 
installed in a wall cabinet. A 1" (2.5 cm) minimum diameter 
hole should have been drilled in the right rear or left rear 
corner of the support surface to pass the appliance cable 
through to the junction box.

NOTE: For undercounter installation, it is recommended that 
the junction box be located in the adjacent right or left 
cabinet. If you are installing the junction box on rear wall 
behind oven, it is recommended that the junction box be 
recessed and located in the upper center of the cabinet.

You can be killed or seriously injured if you don't immediately 
 

You

 

can be killed or seriously injured if you don't follow 

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety 
messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”

These words mean:

follow instructions.

instructions.

DANGER

WARNING

Содержание KEBS209BSS

Страница 1: ...B KEBU109B and KEBU209B Foam strip not included with double oven LocationRequirements IMPORTANT Observe all governing codes and ordinances Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance with oven Recessed installation area must provide complete enclosure around the recessed portion of the oven Grounded electrical supply is required See Electrical ...

Страница 2: ... 74 8 cm for single ovens 27 68 6 cm models A 28 72 8 cm max overall height B 25 64 6 cm max recessed width C 26 67 9 cm recessed height D 23 59 1 cm max recessed depth E 27 68 6 cm overall width 30 76 2 cm models A 28 72 8 cm max overall height B 28 72 4 cm max recessed width C 26 67 9 cm recessed height D 23 59 1 cm max recessed depth E 30 76 2 cm overall width B C D E A 27 68 6 cm models A 27 6...

Страница 3: ... 68 6 cm models A 27 68 6 cm min cabinet width B 1 2 5 cm top of cutout to bottom of upper cabinet door C 14 37 5 cm bottom of cutout to floor is recommended 4 14 10 2 37 5 cm bottom of cutout to floor is acceptable D 25 64 8 cm cutout width E 1 3 8 cm min bottom of cutout to top of cabinet door F 50 127 6 cm recommended cutout height G 24 60 7 cm cutout depth 30 76 2 cm models A 30 76 2 cm min ca...

Страница 4: ... sheathed copper cable with grounding wire See Make Electrical Connection section Flexible conduit from the oven should be connected directly to the junction box Fuse both sides of the line Do not cut the conduit The length of conduit provided is for serviceability of the oven A UL listed or CSA approved conduit connector must be provided If the house has aluminum wiring follow the procedure below...

Страница 5: ...cation RemoveOvenDoor IMPORTANT Use both hands to remove oven door s 1 Open the oven door 2 Locate the oven door latches in both corners of the oven door and rotate the latches forward to the unlocked position 3 Grasp the edges of the oven door with both hands and close the oven door until it will no longer close Lift and pull oven door toward you and remove Set the oven door s aside on a covered ...

Страница 6: ...trical Connection section Cutout Height is between 28 72 8 cm and 29 74 8 cm 1 Using 2 or more people place the oven on its back on a covered surface 2 Remove the foot from the right front spacer by removing the 8 18 x screw NOTE Do not remove the spacer 3 Rotate the foot 90 so the short side of the foot is positioned toward the top of the oven 4 Reinstall the foot to the spacer using the 8 18 x s...

Страница 7: ...m Refer to the following instructions to position the feet for the size of your cabinet cutout Cutout height is between 48 124 1 cm and 50 128 1 cm The oven feet do not need to be installed The oven is configured correctly as received NOTE Do not remove the spacers Go to the Make Electrical Connection section Cutout Height is between 50 128 2 cm and 51 129 9 cm 1 Using 2 or more people place the o...

Страница 8: ...front foot on the right front of the oven 6 Using 2 or more people place the oven in its upright position 7 Go to the Make Electrical Connection section Cutout Height is between 51 130 0 cm and 52 132 6 cm 1 Using 2 or more people place the oven on its back on a covered surface 2 Install a foot on the left rear spacer using a 8 18 x screw NOTE Position the foot so the short side of the foot is fac...

Страница 9: ... listed or CSA approved conduit connector to the junction box 5 Route the flexible conduit from the oven to the junction box through a UL listed or CSA approved conduit connector 6 Tighten screws on conduit connector 7 See Electrical Connection Options Chart to complete installation for your type of electrical connection A Front foot B 8 18 x screw C Spacer A B C For Double Ovens For Single Ovens ...

Отзывы: