
4-7
To access the terminal block, shunt clip and
thermofuses:
1. Unplug cooktop or disconnect
power.
a) Remove the cooktop from
installation.
b) Remove cooktop glass.
c) Remove the elements
d) Remove screws and lift the aluminum
plate.
e) The terminal block, shunt clip and
thermofuses are now accessible,
see figure 1.
Terminal Block, Capacitor, Shunt Clip and Thermofuses
Figure 1
Terminal Block
Thermofuses
Shunt
Capacitor
Thermofuse
Electrical connection to EMI (Filter) Board
Electrical connection to EMI (Filter) Board
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Содержание GIC3051X
Страница 4: ... iv NOTES ...
Страница 20: ...3 6 NOTES ...
Страница 28: ...4 8 NOTES ...
Страница 40: ...6 8 NOTES ...
Страница 42: ...7 2 NOTES ...
Страница 44: ......