Make Gas Connection

1. Assemble flexible connector from gas supply pipe to pressure 

regulator located in the middle front of the range.

2. Apply pipe-joint compound made for use with LP gas to the 

smaller thread ends of the flexible connector adapters (see B 
and G in the following illustration). 

3. Attach one adapter to the gas pressure regulator and the 

other adapter to the gas shutoff valve. Tighten both adapters.

4. Use a 

¹⁵⁄₁₆

" combination wrench and channel lock pliers to 

attach the flexible connector to the adapters. Check that 
connector is not kinked.   

Complete Connection

1. Open the manual shutoff valve in the gas supply line. The 

valve is open when the handle is parallel to the gas pipe.

2. Test all connections by brushing on an approved 

noncorrosive leak-detection solution. If bubbles appear, a 
leak is indicated. Correct any leak found.

3. Remove cooktop burner caps, grates and simmer plate from 

parts package. Align notches in burner caps with pins in 
burner base. Burner caps should be level when properly 
positioned. If burner caps are not properly positioned, 
surface burners will not light. Place burner grates over 
burners and caps.

4. Turn on power supply. “PF” should appear on the clock 

display. For further information, please refer to the user 
instructions located in the Use and Care Guide.

Electronic Ignition System

Initial lighting and gas flame adjustments

Cooktop and oven burners use electronic igniters in place of 
standing pilots. When the cooktop control knob is turned to the 
“LITE” position, the system creates a spark to light the burner. 
This sparking continues, as long as the control knob is turned to 
“LITE.”

Check Operation of Cooktop Burners

Push in and turn each control knob to the “LITE” position. 

The flame should light within 4 seconds. The first time a burner is 
lit it may take longer than 4 seconds to light because of air in the 
gas line. 

If burners do not light properly:

Turn cooktop control knob to the “OFF” position. 

Check that the range is plugged in and the circuit breaker has 
not tripped or the fuse has not blown. 

Check that the gas shutoff valves are set to the “open” 
position. 

Check that burner caps are properly positioned on burner 
bases.

Repeat start-up. If a burner does not light at this point, contact 
your dealer or authorized service company for assistance.

A. Gas pressure regulator
B. Use pipe-joint compound.

C. Adapter (must have ½" male 

pipe thread)

D. Flexible connector

E. Manual gas shutoff valve

F. ½" or ¾" gas pipe

G. Use pipe-joint compound.

H. Adapter

A. Closed valve
B. Open valve

A

B

C

D

E

F

G

H

A

A. Burner base
B. Burner cap

C. Burner grate
D. Simmer plate

A

B

C

D

Содержание 9760618

Страница 1: ...OFF F F O O F FF F O OFF F F O O F FF F O OFF F F O OFF F F O OFF F O OFF F O IMPORTANT Save for local electrical inspector s use Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT À conserver pour consultation par l inspecteur local des installations électriques Installateur Remettre les instructions d installation ...

Страница 2: ...lation de la bride antibasculement 22 Fixation du dosseret ou de la garniture en îlot 22 Raccordement à la canalisation de gaz 23 Système d allumage électronique 24 Réinstallation de l évent du fond 25 Achever l installation 25 SCHÉMAS DE CÂBLAGE 26 RANGE SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety mes...

Страница 3: ...r WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions In the State of Massachusetts the following installation instructions apply Installations and repairs must be performed by a qualified or licensed...

Страница 4: ... codes and ordinances Do not obstruct flow of combustion and ventilation air It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located on the right vertical surface of the oven door frame It is recommended that a 600 CFM range hood be installed above the range Recessed installations must provide c...

Страница 5: ...8 cm beyond 24 61 cm base cabinet Cabinet Dimensions Cabinet opening dimensions shown are for 25 64 cm countertop depth 24 61 cm base cabinet depth and 36 91 4 cm countertop height IMPORTANT If installing a range hood above the range follow the range hood instructions for dimensional clearances above the cooktop surface NOTE Receptacle must be rotated 90 for Canadian installation NOTE 42 106 7 cm ...

Страница 6: ...box See Make Electrical Connection Locate the junction box to allow as much slack as possible between the junction box and the range so that the range can be moved if servicing is ever necessary Do not cut the conduit A UL listed or CSA approved conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with...

Страница 7: ... must be used Do not use TEFLON tape With LP gas piping or tubing size can be 1 3 cm minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector If local codes permit a new CSA design certified 4 5 ft 122 152 4 cm long 1 6 cm or 1 9 cm I D flexible metal appliance connector may be used for connecting range to the gas supply line A 1 3 cm ...

Страница 8: ...g its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa INSTALLATION INSTRUCTIONS UnpackRange 1 Remove shipping materials tape and film from range Keep shipping pallet under range Remove oven racks grates and parts package from inside oven 2 Remove the 2 screws on each side of the top of the bottom vent S...

Страница 9: ...e This range is manufactured with a cabinet connected green or bare ground wire Connect the range cable to the junction box through the UL listed or CSA approved conduit connector 1 Disconnect power 2 Remove junction box cover if present 3 Install a UL listed or CSA approved conduit connector to the junction box 4 Route the flexible cable conduit from the range to the junction box using a UL liste...

Страница 10: ...t opening 2 Remove cardboard or hardboard from under range Move range into its final location 3 Attach the backguard or island trim as required for your installation See Tools and Parts Attachment screws are included in the package containing literature Attaching the Backguard Attaching the Island Trim 4 Using 2 or more people tip the range back so that the front feet lift off the ground Slide ran...

Страница 11: ...lay For further information please refer to the user instructions located in the Use and Care Guide ElectronicIgnitionSystem Initial lighting and gas flame adjustments Cooktop and oven burners use electronic igniters in place of standing pilots When the cooktop control knob is turned to the LITE position the system creates a spark to light the burner This sparking continues as long as the control ...

Страница 12: ... and hold hand above oven floor and feel for heat Do not touch oven floor Press CANCEL and turn oven selector to RESET Check Operation of Oven Broil Element 1 Close the oven door 2 Turn oven selector to BROIL HI will appear in the temperature display 3 Press ENTER Look through oven window The top element should glow red and heat should be radiating out of the door Press CANCEL and turn oven select...

Страница 13: ...g material Dry thoroughly with a soft cloth For more information see the Range Care section of the Use and Care Guide 9 Read Range Use in the Use and Care Guide 10 Turn on surface burners and oven See the Use and Care Guide for specific instruction on range operation If range does not operate check the following Household fuse has not blown or circuit breaker has not tripped Gas valves are turned ...

Страница 14: ...14 Oven Schematic Blower remains off until oven reaches 190 F 88 C and may continue running up to 45 minutes after oven has turned off NOTE Circuit is shown in standby off mode with oven door closed ...

Страница 15: ...15 Notes ...

Страница 16: ...VERTISSEMENT Si les renseignements dans ce manuel ne sont pas exactement observés un incendie ou une explosion peut survenir causant des dommages au produit des blessures ou un décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d all...

Страница 17: ...n Vérifier les codes locaux et consulter le fournisseur de gaz Vérifier l alimentation en gaz et l alimentation électrique existantes Voir les sections Spécifications électriques et Spécifications de l alimentation en gaz Toutes les connexions électriques doivent être effectuées par un électricien qualifié et certifié Dans l État du Massachusetts les instructions d installation suivantes sont appl...

Страница 18: ...sous la cuisinière une plaque d appui isolée ou une plaque de contreplaqué de 0 64 cm IMPORTANT Pour éviter tout dommage consulter le constructeur ou le fabricant du placard pour déterminer si les matériaux utilisés ne subiront pas un changement de couleur une déstratification ou d autres dommages Ce four a été conçu conformément aux exigences UL et aux normes de la CSA International il respecte l...

Страница 19: ... canadien de l électricité et de tout code ou règlement local en vigueur On peut obtenir un exemplaire de la norme ci dessus auprès de Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA En cas de doute quant à la qualité de la liaison à la terre de la cuisinière consulter un électricien qualifié Lorsqu une source d électricité monophasée de 208 240 volts 60 Hz 4 conducteurs ...

Страница 20: ...s En général le fournisseur de gaz propane détermine les matériaux à utiliser et le diamètre approprié Raccord métallique flexible Si le code local le permet on peut utiliser pour raccorder la cuisinière à la canalisation de gaz un raccord métallique flexible neuf homologation CSA de 4 5 pi 122 152 4 cm de longueur de diamètre interne de 1 6 cm ou 1 9 cm Un raccord avec filetage mâle de 1 3 cm est...

Страница 21: ...n robinet d arrêt manuel individuel INSTRUCTIONS D INSTALLATION Déballagedelacuisinière 1 Ôter les matériaux d emballage le ruban adhésif et le film protecteur de la cuisinière Maintenir la palette d expédition sous la cuisinière Retirer les grilles de four et le sachet de pièces de l intérieur du four 2 Ôter les 2 vis de chaque côté de la partie supérieure de l évent du fond Faire glisser l évent...

Страница 22: ... longues peuvent être nécessaires Des vis plus longues sont disponibles auprès de votre quincaillerie locale Fixationdudosseretoudelagarnitureenîlot 1 À deux personnes ou plus déplacer la cuisinière près de l ouverture d encastrement 2 Retirer le carton ou le panneau de fibre dur de sous la cuisinière Déplacer la cuisinière à son emplacement final 3 Fixer le dosseret ou la garniture en îlot en fon...

Страница 23: ...êt manuel sur la canalisation de gaz la manette doit être parallèle au tuyau 2 Effectuer une recherche des fuites appliquer au pinceau sur les connexions une solution non corrosive de détection des fuites la formation de bulles identifiera une fuite Éliminer toute fuite constatée 3 Prendre les chapeaux de brûleur les grilles de brûleur et la plaque de mijotage dans le paquet de pièces Aligner les ...

Страница 24: ...ton de commande 2 Immobiliser la tige de commande avec une pince Utiliser un petit tournevis à lame plate pour faire tourner la vis située au centre de la tige de commande ajuster les flammes à la taille désirée 3 Réinstaller le bouton de commande 4 Tester le fonctionnement du brûleur faire passer le bouton de commande de la position LO bas à la position HI élevé et observer les flammes pour chaqu...

Страница 25: ...rizontal jusqu aux matériaux combustibles derrière la surface de cuisson est inférieur à 1 2 5 cm 7 Vérifier que la cuisinière est raccordée uniquement au type de gaz pour lequel le fonctionnement est agréé 8 Utiliser une solution d eau tiède et de nettoyant ménager doux pour éliminer tout résidu de cire laissé par les matériaux de protection de l emballage Sécher parfaitement avec un linge doux P...

Страница 26: ...ebranchement pourrait provoquer un fonctionnement incorrect et une situation dangereuse Le cordon d alimentation sur cet appareil est équipé d une fiche à 3 alvéoles reliée à la terre qui s adapte à toute prise standard à 3 alvéoles reliée à la terre Vérifier le bon fonctionnement de l appareil après l intervention Schéma de câblage de la table de cuisson ...

Страница 27: ...r Le ventilateur reste éteint jusqu à ce que le four atteigne 190 F 88 C et peut continuer de fonctionner jusqu à 45 minutes après que le four est éteint REMARQUE Circuit illustré en mode d attente arrêt avec porte du four fermée ...

Страница 28: ... réservés Registered Trademark TM Trademark of KitchenAid U S A KitchenAid Canada licensee in Canada Marque déposée TM Marque de commerce de KitchenAid U S A Emploi sous licence par KitchenAid Canada au Canada 6 08 Printed in U S A Imprimé aux É U ...