1.  INTRODUCTION 

Thank you for purchasing the 

KISAE  Abso  DC  to  DC  Battery  Charger

. With our state of the art, 

easy to use design, this product will offer you reliable service for providing a multi-stage, multi-input 
battery  charger  to  charge  the  different  types  of  batteries  you  have  installed  in  either  your  home, 
boats, RV caravan, 4WD or commercial vehicle. This manual will explain how to use this unit safely 
and effectively. 

2.  PRODUCT DESCRIPTION 

The DC to DC Battery Charger includes the items list below: 

  Base unit 

Model 

 Maximum Output Rating 

Battery Input Voltage 

Maximum Solar Input 

DMT1230 

12V 30A 

12V or 24V (Auto Ranging) 

50Voc, 30A 

DMT1250 

12V 50A 

DMT2430 

24V 30A 

  O

wner’s manual 

3.  UNDERSTANDING THE UNIT 

The DC to DC Battery Charger is a fully automatic multi-stage, multi-input battery charger with the 
ability  to  charge  from  either  an  alternator  linked  to  a  battery,  or  via  solar  power  with  its  built-in  
Maximum  Power  Point  Tracking  (MPPT)  Solar  Controller.  With  two  inputs  available,  the  house 
battery  will  be  charged  from  either  the  engine  while  underway,  or  via  the  solar  panels  when 
stationary.  The  process  to  choose  either  engine  or  solar  is  fully  automatic  and  both  functions  are 
controlled from within the unit itself without the need for external relays.  
During normal operation the DC to DC Battery Charger will do a full charge cycle to float stage on 
the House Battery Bank with ability to choose either GEL, AGM, Flooded, Custom Programmable or 
Lithium. Once the float stage is reached the charger transitions to a power supply mode to support 
any on-board DC loads. 

Multi-stage Charging Process 

– GEL, AGM, Flooded & Program Modes 

The DC to DC Battery Charger is a fully automatic, set and forget charger. It is designed to quickly 
and  accurately  recharge  your  deep  cycle  batteries  utilizing  charger  algorithms  that  help  to 
maximize the life of your specialized deep cycle batteries. 
The  DC  to  DC  Battery  Charger  features  multi-stage  smart  charging  technology  that  enables  the 
charger  to  be  connected  to  your  House  Battery  Bank  permanently.  With  the  input  of  multiple 
sources,  you  can  be  assured  of  charging  your  batteries  whenever  underway;  or  when  the  sun  is 
shining on your solar array. 
As  dictated  by  battery manufacturer  recommendations,  deep  cycle batteries  require  a multi-stage 
charge sequence for perfect, fast and accurate charging. The DC to DC Battery Charger delivers 
three primary charge stages: 

Stage  1 

– Bulk or Boost  charge:

 The battery is charged at full rated output current of the charger (as per the 

setting)  until  the  battery  reaches  its  final  charging  voltage,  known  as  its  absorption  voltage.  In  this 
step, around 80% of the battery is recovered as fast as possible.  

Stage  2 

–  Absorption  Charge:

  With  the  charger  voltage  held  steady,  the  remaining  20%  of  the  battery  is 

replaced with the charger allowing the current to taper off as the battery approaches full charge. 

Stage 3 

– Float:

 In the float stage the charger voltage is lowered and held at a constant and safe predetermined 

level.  This  prevents  the  battery  from  being  overcharged,  yet  allows  the  charger  to  supply  enough 
current to make up for the self-discharge losses of the battery, while supporting any additional loads 
connected to the battery (such as DC lighting and refrigerators). This stage allows the charger to be 
used as a DC power supply.  

A full recharge cycle will occur when the House Battery Bank voltage drops to below 12.5Vdc on 

DMT1230

1250

 or 25.0Vdc on 

DMT2430

.

 

Lithium Charging Process 

The DC to DC Battery Charger has a specific charging profile for Lithium batteries. It has its own 
charging voltage and current settings that needs to be set by the user. It also requires the user to 
set  the charger  termination 

current (“L” setting) to pass from Absorption to Float stage. Once the 

user defined charge voltage is reached, the charger will start reducing the current output and the 
charging process will terminate when the charging current drops to the set termination (

“L”) current. 

This can take anywhere between 3 to 25 minutes, depending on the capacity (size) of the battery 
bank  and  its initial  state  of charge.  The  unit  will  then  act  as  a  power  supply  to support  additional 
loads  connected  to  the  battery.  A  bulk  re-start  will  occur  when  the  House  Battery  Bank  voltage 
drops to below 13.3Vdc on 

DMT1230/DMT1250

 or 26.6Vdc on 

DMT2430

Содержание DMT1230

Страница 1: ...Abso DC to DC Battery Charger 12V 30A DMT1230 12V 50A DMT1250 24V 30A DMT2430 Owner s Manual...

Страница 2: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may c...

Страница 3: ...ents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 UNDERSTANDING THE UNIT 5 4 INSTALLING THE CHARGER 8 5 CONNECTING THE CHARGER 8 6 UNIT OPERATION 10 7 SPECIFICATIONS 16 8 WARRANTY 17 Appendix A1 18 Appe...

Страница 4: ...on WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gases such as propane tanks or large engines Avoid covering the ventilation openings Always operate unit in an ope...

Страница 5: ...the input of multiple sources you can be assured of charging your batteries whenever underway or when the sun is shining on your solar array As dictated by battery manufacturer recommendations deep cy...

Страница 6: ...er for equalization recommendations Bulk Absorption Absorption Float Stage Current Setting The Bulk Absorption Bulk Abs and Absorption Float Abs Float Stage current settings are based on the House Bat...

Страница 7: ...the highest available current setting for battery protection Program Type House Battery Bank Voltage and Current Setting WARNING FIRE HAZARD When choosing the Program Battery type you can set to a wi...

Страница 8: ...ertically Battery Terminals facing downwards to provide adequate drip protection Use the base of the charger as a mounting template to mark the positions of the fixing screws Drill the 4 fixing holes...

Страница 9: ...e Battery bank Connect the CH1 terminal to the negative terminal of the House Battery Bank Make all the and wire connections on CH2 Solar Array Panel and CH3 Alternator Start battery See more details...

Страница 10: ...eturns to 13 2V on a 12V Input system or 26 4V on a 24V Input system Note B When the unit has activated the battery charging process using the Control terminal or using the Manual Override through the...

Страница 11: ...e i e 13 2V 12 3V on 12V CH3 battery system or 26 4 24 6V on 24V CH3 battery system under Normal Priority mode respectively and it is not the charging source of the House Battery bank yet It will chan...

Страница 12: ...ven better a one indicating engine running to the Control terminal of the charger so to make sure that the Override Mode is activated only when the engine alternator is running This automatic setting...

Страница 13: ...oltage is automatically adjusted as per the following table Measured Battery Temperature Automatic Battery Charging Voltage Adjustment from 25 C Flooded and GEL type AGM type 25 C 0 027V C 0 021V C 25...

Страница 14: ...Please notice that using a jumper to connect the positive terminal of CH 1 and CH 2 will stop the control and regulation functions of the house battery Therefore keep this temporary bypass to increase...

Страница 15: ...low 15 5V 31V respectively This may be due to charging from another charging source i e Another solar controller or AC battery charger with either an excessively higher voltage regulation setting or a...

Страница 16: ...200 uA Battery Temperature Setting Low Normal High automatically overridden with optional BTS Efficiency 95 Minimum Operating Voltage 8 0 Vdc 16 0 Vdc DC Input Solar Array Panels CH2 Solar Input Volta...

Страница 17: ...epresentative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufa...

Страница 18: ...REV D Page 18...

Страница 19: ...REV D Page 19...

Страница 20: ...REV D Page 20...

Страница 21: ...REV D Page 21...

Страница 22: ...REV D Page 22...

Страница 23: ...REV D Page 23...

Страница 24: ...REV D Page 24 Printed in China...

Отзывы: