background image

 

 

REV D

                                                                                                                                                                                                     Page 

17                          

 

 

8.  WARRANTY 

One Year Limited Warranty 

The  limited  warranty  program  is  the  only  one  that  applies  to  this  unit,  and  it  sets  forth  all  the 
responsibilities  of 

KISAE

.  There  is  no  other  warranty,  other  than  those  described  herein.  Any 

implied  warranty  of  merchantability  of  fitness  for  a  particular  purpose  on  this  unit  is  limited  in 
duration to the duration of this warranty.  
This  unit  is  warranted,  to  the  original  purchaser  only,  to  be  free  of  defects  in  materials  and 
workmanship for one year from the date of purchase without additional charge. The warranty does 
not extend to subsequent purchasers or users. 
Manufacturer  will  not  be  responsible  for  any  amount  of  damage  in  excess  of  the  retail  purchase 
price  of  the  unit  under  any  circumstances.  Incidental  and consequential  damages  are specifically 
excluded from coverage under this warranty.  
This unit is not intended for commercial use. This warranty does not apply to damage to units from 
misuse  or  incorrect  installation/connection.  Misuse  includes  wiring  or  connecting  to  improper 
polarity power sources. 

  

RETURN/REPAIR POLICY: 

If  you  are  experiencing  any  problems  with  your  unit,  please  contact  our  customer  service 
department  at  [email protected]  or  phone  1  877  897-5778  before  returning  product  to 
retail  store.  After  speaking  to  a  customer  service  representative,  if  products  are  deemed  non-
working or malfunctioning, the product may be returned to the purchasing store within 30 days of 
original purchase. Any defective unit that is returned to manufacturer within 30 days of the date of 
purchase will be replaced free of charge.  
If  such  a  unit  is  returned  more  than  30  days  but  less  than  one  year  from  the  purchase  date, 
manufacturer  will  repair  the  unit  or,  at  its  option,  replace  it,  free  of  charge.  If  the  unit  is  repaired, 
new  or  reconditioned  replacement  parts  may  be  used,  at 

manufacturer’s  option.  A  unit  may  be 

replaced  with  a  new  or  reconditioned  unit  of  the  same  or  comparable  design.  The  repaired  or 
replaced  unit  will  then  be  warranted  under  these  terms  for  the  remainder  of  the  warranty  period. 
The customer is responsible for the shipping charges on all returned items.  

 

LIMITATIONS: 

This  warranty  does  not  cover  accessories,  such  as  adapters  and  batteries,  damage  or  defects 
result from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due 
to  usage  or  exposure  to  sunlight),  accidents,  damage  during  shipping  to  our  service  facility, 
alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care 
and maintenance, fire and flood. 
If  your  problem  is  not  covered  by  his  warranty,  contact  our  Customer  Service  Department  at                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              
[email protected] or 1 877 897-5778 for general information if applicable. 

 
 
 
 
 
 

Service Contact Information 

Email:[email protected] 

Phone: 1-877-897-5778 

www.kisaepower.com

 

 
 
 
 

 

 
 

Содержание DMT1230

Страница 1: ...Abso DC to DC Battery Charger 12V 30A DMT1230 12V 50A DMT1250 24V 30A DMT2430 Owner s Manual...

Страница 2: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may c...

Страница 3: ...ents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 UNDERSTANDING THE UNIT 5 4 INSTALLING THE CHARGER 8 5 CONNECTING THE CHARGER 8 6 UNIT OPERATION 10 7 SPECIFICATIONS 16 8 WARRANTY 17 Appendix A1 18 Appe...

Страница 4: ...on WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gases such as propane tanks or large engines Avoid covering the ventilation openings Always operate unit in an ope...

Страница 5: ...the input of multiple sources you can be assured of charging your batteries whenever underway or when the sun is shining on your solar array As dictated by battery manufacturer recommendations deep cy...

Страница 6: ...er for equalization recommendations Bulk Absorption Absorption Float Stage Current Setting The Bulk Absorption Bulk Abs and Absorption Float Abs Float Stage current settings are based on the House Bat...

Страница 7: ...the highest available current setting for battery protection Program Type House Battery Bank Voltage and Current Setting WARNING FIRE HAZARD When choosing the Program Battery type you can set to a wi...

Страница 8: ...ertically Battery Terminals facing downwards to provide adequate drip protection Use the base of the charger as a mounting template to mark the positions of the fixing screws Drill the 4 fixing holes...

Страница 9: ...e Battery bank Connect the CH1 terminal to the negative terminal of the House Battery Bank Make all the and wire connections on CH2 Solar Array Panel and CH3 Alternator Start battery See more details...

Страница 10: ...eturns to 13 2V on a 12V Input system or 26 4V on a 24V Input system Note B When the unit has activated the battery charging process using the Control terminal or using the Manual Override through the...

Страница 11: ...e i e 13 2V 12 3V on 12V CH3 battery system or 26 4 24 6V on 24V CH3 battery system under Normal Priority mode respectively and it is not the charging source of the House Battery bank yet It will chan...

Страница 12: ...ven better a one indicating engine running to the Control terminal of the charger so to make sure that the Override Mode is activated only when the engine alternator is running This automatic setting...

Страница 13: ...oltage is automatically adjusted as per the following table Measured Battery Temperature Automatic Battery Charging Voltage Adjustment from 25 C Flooded and GEL type AGM type 25 C 0 027V C 0 021V C 25...

Страница 14: ...Please notice that using a jumper to connect the positive terminal of CH 1 and CH 2 will stop the control and regulation functions of the house battery Therefore keep this temporary bypass to increase...

Страница 15: ...low 15 5V 31V respectively This may be due to charging from another charging source i e Another solar controller or AC battery charger with either an excessively higher voltage regulation setting or a...

Страница 16: ...200 uA Battery Temperature Setting Low Normal High automatically overridden with optional BTS Efficiency 95 Minimum Operating Voltage 8 0 Vdc 16 0 Vdc DC Input Solar Array Panels CH2 Solar Input Volta...

Страница 17: ...epresentative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufa...

Страница 18: ...REV D Page 18...

Страница 19: ...REV D Page 19...

Страница 20: ...REV D Page 20...

Страница 21: ...REV D Page 21...

Страница 22: ...REV D Page 22...

Страница 23: ...REV D Page 23...

Страница 24: ...REV D Page 24 Printed in China...

Отзывы: