background image

Содержание TR850

Страница 1: ......

Страница 2: ...ur purchasing TR850 TR850G produced by Kirisun Communications Co Ltd We believe TR850 TR850G can bring great convenience to your life and work TR850 TR850G DMR repeater which always incorporates the advanced technology and exquisite craft we hope that the quality and function of this product could make you feel satisfied ...

Страница 3: ...ng certificate Kirisun and the authorized parties own the related intellectual property of all the product parts include accessories Any design and materials may not be modified copied extracted or translated without the authorization of Kirisun or its authorized parties Due to the update or modification of the product Kirisun owns the right to change the specifications of software and hardware de...

Страница 4: ...semble the radio by yourself The repeater setting and mounting must be approved by the local Radio Management Departments Installing the antenna of repeater must be do well of lightning protection otherwise life or property damage may be occurred Please use the qualified power antenna lightning protection device power divider and corresponding accessories and make sure they are installed correctly...

Страница 5: ...struction 5 2 2 2 External Connector Instruction 7 2 3 LED Indicators 8 3 Basic Operations 9 3 1 Powering On Off 9 3 2 Voice and Data Transfer 9 3 3 IP Connecting 9 3 4 Warning 10 3 5 Programming Software 10 3 5 1 File Menu 10 3 5 2 Model Menu 11 3 5 3 Edit Menu 11 4 Program Menu 15 5 Installation Guide refit guide 18 6 Frequently Asked Questions FAQ 22 7 Recommend Duplexer Parameters 23 ...

Страница 6: ...lease unpack carefully and check all the items listed in the following table before discarding the packing material If any damage or loss occurs during shipment please contact your dealer 1 1 Standard Accessories Item Quantity Repeater 1 Foot pad 4 pcs 1 Instruction Manual 1 ...

Страница 7: ...TR850 TR850G DMR Repeater Instruction Manual 2 ...

Страница 8: ...TR850 TR850G DMR Repeater Instruction Manual 3 2 Radio Overview ...

Страница 9: ... 4 No Part Name 1 Handles 2 Frond Panel LED Indicators 3 Power Switch 4 GPS Antenna Connector 5 ACCY Connector 6 Network Connector IP 7 100 240V AC Cable Connector 8 GND Screw 9 Tx Connector 10 Fan 11 Cooler 12 RX Connector 13 13 6V DC Connector ...

Страница 10: ...TR850 TR850G DMR Repeater Instruction Manual 5 2 1 Power On Off Button Power on off the repeater 2 2 ACCY Connector 2 2 1 Pin Instruction Pin Instruction PIN1 Undefined PIN2 Undefined 1 9 10 18 19 26 ...

Страница 11: ...2 It is used for test PIN6 ACC_MAP_ID1 It is used for test PIN7 Undefined PIN8 GND PIN9 SPEAKER PIN10 SPEAKER PIN11 MIC PIN12 GND PIN13 Undefined PIN14 Undefined PIN15 Undefined PIN16 GND PIN17 External PTT High level is effective PIN18 GND PIN19 Undefined PIN20 Undefined PIN21 Undefined ...

Страница 12: ...ect the Pin17 with Pin22 of VGA to activate external PTT It can test the transmitting signal of repeater Test Analog Receiving Short connect Pin5 with Pin22 of VGA Reset IP address Short connect PIN6 with PIN22 of VGA to reset the IP and gateway address to the IP address on the label but it will not change data of IP address and gateway address The IP address and gateway address will recover to co...

Страница 13: ...icator Description 1 TX A Slot 1 transmitting indicator 2 RX A Slot 1 receiving indicator 3 TX B Slot 2 transmitting indicator 4 RX B Slot 2 receiving indicator 5 Repeater signal indicator 6 Analog mode indicator 7 Digital mode indicator 8 Alarm indicator 9 Power indicator ...

Страница 14: ...receiving signal into strong transmitting signal and transmit on the same channel When transmitting the light is on If it is analog signal flashes if it is digital signal flashes The receiving and transmitting frequency and CDCSS CTCSS can be set by CPS An analog channel or a smart analog digital detecting channel can be programmed with one group of CDCSS CTCSS encoding and decoding list When rece...

Страница 15: ...cting status should be checked before programming Make sure that the network button in the tools bar is pressed down If the button is not pressed down the IP address bar will be grey disabled also need to make sure the connect button is pressed down the default status of connect and network buttons are pressed down under the status of connect button pressed down the software will connect to the re...

Страница 16: ...ve path similar with save as Save as Select a new path to save the current configuration file Exit Exit the software if the configuration file has not been saved software will ask user to save it 3 5 2 Model Menu Model Type to select a model type which includes the frequencies of 136MHz 174MHz 400MHz 470MHz or custom frequency The custom frequency cannot exceed the range of the frequencies the rep...

Страница 17: ... 500ms the default value is 4000ms Individual Call Hang Time When a terminal radio initiates an individual call and no PTT presses repeater shall hang on for a period of time During this time the channel is being taken up and communication is regarded still going no accept to other signal relay If any presses PTT then the hang time recounts Once the hang time is over this communication is over too...

Страница 18: ...ort The repeaters use the UDP local port to connect to the server The range of the port is 0 65535 Server IP When networking the IP of the server that repeater connects to Server Port The repeater uses TCP server TCP server connects needs a specific server port The range value of the port is from 0 65535 Gateway IP When networking the gateway IP that repeaters interconnect to each other Transmit F...

Страница 19: ...Ratio It is used to shows if it s the antenna match with the radio The default value is 3 0 Bandwidth It s used to select the channel spacing of the current channel Options are 12 5 kHz Colour Code It is used to select the colour code of the current channel As long as the radios with same colour code in the same frequency can communicate with each other Value Range 0 15 default value is 1 Squelch ...

Страница 20: ...hannel 2 Mix channel cannot select CSQ must select CTCSS CDCSS or CDCSS 4 Program Menu Read Data Read data from the repeater When reading data a bar pops up and shows the reading process When finish reading software will pop up a dialog box shows Read data successfully When you try to read data tick the option Exit after finish when finish reading data the dialog box will exit automatically If not...

Страница 21: ...rk is OK otherwise will be shown Network XX Upgrade software the main function is to download different function modules from PC to the repeater then set the main parameters on them Under the Program menu find Program Download then you can upgrade But before upgrading you should select the path of the update package If is a standard update package after select the path each update file s paths wil...

Страница 22: ...o needs For example if the repeater could work normally and connecting the PC network before upgrade then you could remove the hook behind the environment variable 2 Click download button to proceed When upgrading there is a progress bar to show the upgrading status And there will be a prompt message after the process is finished Upgrading the system 1 Boot mode should be 1000 while upgrading Choo...

Страница 23: ...epeater Instruction Manual 18 5 Installation Guide refit guide Duplexer Installation 1 Disassembly As the figure below take off the 4 screws and 6 screws of two sides of the top cover and then slightly open the top cover ...

Страница 24: ...TR850 TR850G DMR Repeater Instruction Manual 19 2 Take off the two screws of duplexer baffle remove the duplexer ...

Страница 25: ...TR850 TR850G DMR Repeater Instruction Manual 20 3 Slightly loosen the two screws of fixed duplexer bracket on installed clapboard to the bracket and do not too loosen Refer to following figure ...

Страница 26: ...on Manual 21 4 Fixed the duplexer tail screws to the duplexer bracket Push the duplexer to the end three duplexer connection holes until the duplexer is locked Then fasten the duplexer bracket and install screw Refer to following figure ...

Страница 27: ... Questions FAQ Can t connect to the PC programming software The IP of repeater input is error in the programming software Or the user forgets the IP of repeater Can t transfer Please confirm the frequency and the working mode of the radio is the same with the repeater ...

Страница 28: ...del SGQ 450 A D Frequency Range MHz 380 520 Bandwidth KHz 400 Frequency Spacing MHz 10 Insertion Loss dB 1 0 Isolation dB 80 Suppression dB 80 V S W R 1 3 NormaI lmpedance Ω 50 Max Power Input W 30 50 Standard Termination N BNC Dimensions mm 223 154 31 5 223 191 39 Weight KG 1 2 2 0 ...

Страница 29: ...lled environment This equipment should be installed and operated with minimum distance 1 0m between the radiator your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to prov...

Страница 30: ...user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help ...

Отзывы: