![Kirby Morgan M-48 SuperMask Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/kirby-morgan/m-48-supermask/m-48-supermask_user-manual_1971905015.webp)
Diving Modes
© MMXXI Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 210902001
15
–
Topside air supply (either low
pressure compressor or high-
pressure cylinders)
–
Air control manifold
–
Diver’s Manifold Block with One
Way Valve (Non-Return)
–
Diver worn bail-out bottle with
diving harness
–
Bail-out regulator with over-
pressure relief valve
–
Umbilical with breathing gas
supply hose, communications
wire, and pneumofathometer
hose
–
Communications box
–
M-48 SuperMask
®
equipped with
communications
B
WARNING
The M-48 SuperMask
®
is NOT equipped with a one-way
valve (non-return) for surface supplied diving. When using
the mask for surface supplied diving it must be used with
the KMDSI Manifold Block KMDSI P/N 300-145, 300-150,
or 300-155, a suitable diving harness and emergency gas
supply system. Without the one-way valve (non-return),
the diver could be subject to a “squeeze” if the umbilical
supply is severed. This can be fatal.
Demand Regulator Adjustment / Surface Supplied
When using the mask for surface supplied diving, the KMDSI Balanced
SCUBA regulator will offer the best overall performance due to the broad
adjustment range of the regulator bias adjustment and the ability to make
adjustments for variations in supply pressure.