background image

REX Regulator (KM47/77)

Содержание Dive Lab KM47

Страница 1: ...REX Regulator KM47 77 ...

Страница 2: ...served This manual is made available for the express use of owner of this Kirby Morgan product No part of this manual may be reproduced stored in any retrieval system or transmitted or used in any form or by any means whether graphic electronic mechanical photocopy or otherwise by technology known or unknown without the prior written permission of Kirby Morgan Dive Systems Inc THIS SLIDE SHOW IS F...

Страница 3: ...helmets and masks is simple and highly reliable The fact that they can continue to operate when the components are not in a well maintained condition can cause divers to become complacent about maintenance Your life depends on the correct function of this equipment ...

Страница 4: ...n like any type of life support equipment it requires regular periodic maintenance to function properly All parts disassembled should be thoroughly cleaned Components that require the use of lubricants sealing and thread locking compounds should also be serviced ...

Страница 5: ...ps from whisker wings Remove whisker valve assembly from each side of exhaust body inspect During regular cleaning and inspection the whisker valves do not need to be removed from plastic exhaust valve seats Remove regulator cover ring cover washer and diaphragm ...

Страница 6: ...REX Regulator KM47 77 Disassembly ...

Страница 7: ...REX Regulator KM47 77 Disassembly ...

Страница 8: ... each plastic valve cage with the silicone valve still installed Clean and inspect valve assemblies Silicone valves should be smooth and flat when lifted away from seat it should snap firmly into place The seats should be smooth and straight ...

Страница 9: ...justment knob in clockwise all the way then rotate it out counter clockwise three turns Slowly rotate the inlet nipple in clockwise until a slight movement is noticed at the roller lever then stop Lightly tighten the jam nut to prevent movement of the nipple tube ...

Страница 10: ...REX Regulator KM47 77 Set up Adjustment Install diaphragm thrust washer flexible cover and cover ring to the regulator assembly using the special spanner wrench ...

Страница 11: ... done using a supply pressure of between 135 140 p s i g Re check adjustment knob position by completely turning it in then backing it out 3 full turns Attach a air source to either umbilical adapter at the one way valve or EGS valve Slowly pressurize helmet then open the supply fully ...

Страница 12: ...of an inch before gas flow is heard Once desired travel is achieved tighten lock nut against regulator body using two 13 16 wrenches Make certain bent tube fitting is snug against the hex on nipple tube by again using two 13 16 wrenches Re check purge adjustment re adjust if needed ...

Страница 13: ...X Regulator KM47 77 Set up Adjustment Low pressure air source must be adjustable over a range from 135 140 p s i With the air supply connected turn the adjustment knob all the way out and back in 3 turns ...

Страница 14: ...REX Regulator Regulator is adjusted and ready for use ...

Страница 15: ...Summary Inspection Adjustments Always refer to Operations maintenance manual for adjustment procedures ...

Страница 16: ... ...