EN UG-020 Link 6 user guide r1.0
258
• 1 x Emergency stop station
• 1 x Cable
Tools
• Ferrule (optional)
About this task
View or download publications at
.
Procedure
1.
Make sure the
is switched off.
2.
Connect the
E-stop
to the controller. Use the wire order on the E-stop connector.
Terminal (Controller side)
Wire color
Pin (Device side)
A1
Black
2
A2
Red
1
B1
White
4
B2
Yellow
3
3.
Connect the 4-pin connector to the Emergency stop station.
Related topics
on page 78
External 3-position enabling device
The external 3-position
is an optional component that provides enabling device
functions in case the
is not used. It is connected directly to the terminals in the
It is connected directly to the terminals in the controller.
Photo: IDEC
Figure 215: IDEC HE1G-21SM
Related topics
on page 78
+1 514-277-3777
kinovarobotics.com
© 2022 Kinova inc. All rights reserved.