ParaBeam 410 & 210 DMX
Operation Manual
Part No. 3100064 Rev A 05-10-2012
®
ParaBeam 410 Center Mount
ParaBeam 410 Pole-Op
Страница 1: ...ParaBeam 410 210 DMX Operation Manual Part No 3100064 Rev A 05 10 2012 ParaBeam 410 Center Mount ParaBeam 410 Pole Op ...
Страница 2: ...120VAC PAR 410P 230 ParaBeam 410 DMX Pole Op 230VAC PAR 410Y 120 ParaBeam 410 DMX Yoke Mount 120VAC PAR 410Y 230 ParaBeam 410 DMX Yoke Mount 230VAC PAR 210 120 ParaBeam 210 DMX Center Mount 120VAC PAR 210 230 ParaBeam 210 DMX Center Mount 230VAC PAR 210P 120 ParaBeam 210 DMX Pole Op 120VAC PAR 210P 230 ParaBeam 210 DMX Pole Op 230VAC PAR 210Y 120 ParaBeam 210 DMX Yoke Mount 120VAC PAR 210Y 230 Par...
Страница 3: ...ParaBeam 410 Gel Frame Included GFR P2 ParaBeam 210 Gel Frame Included LVR P4 S ParaBeam 410 Silver Louver Included LVR P2 S ParaBeam 210 Silver Louver Included 3 True Match Lamps 55C K32 55W Kino KF32 Compact 55C K55 55W Kino KF55 Compact ...
Страница 4: ...Beam 410 DMX Center Mount 1 Lamp Case 1 Ship Case Dimensions Weight 29 5 x 11 x 29 5 61 lb 75 x 28 x 75cm 27 5kg KIT P2 120 ParaBeam 210 DMX Center Kit 120VAC KIT P2 230 ParaBeam 210 DMX Center Kit 230VAC Kit Contents 1 ParaBeam 210 DMX Center Mount 1 Lamp Case 1 Ship Case Dimensions Weight 21 5 x 11 5 x 29 45 lb 54 6 x 29 2 x 73 6cm 20 3kg ...
Страница 5: ...ver or honeycomb louver fits into front channel Insert lamp end first Push tab down and forward to lock into open position Insert gel frame into channel closest to lamps Close reflector door To release lamps press Red button and lift lamp out All 4 retaining tabs must be extended to lock accessories in place ...
Страница 6: ... Center Mount includes a lollipop w Baby Receiver MTP LB and can hang from a grid by a baby pipe hanger or mount onto a baby stand A 180 degree turn is all that is required to loosen the mount for orientation To adjust the tension on the lock lever pull handle away from mount This disengages the handle from the screw mechanism and allows the lever to be reoriented You can also use a screwdriver to...
Страница 7: ...y and best color rendering DO NOT operate fixtures with lamp base in the down position Color can diverge up to 400K and will get very green HORIZONTAL MODE Even in the horizontal position a slight rotation favoring the lamp tips lamp base higher than the lamp tip will allow for better color temperature stability Note When looking at the back of the fixture the Kino Flo logo should read If the Logo...
Страница 8: ... hanger using a Baby Receiver Assembly for Yoke MTP I40 also sold separately The ParaBeam 410 and 210 Pole Op fixtures include a yoke with an attached junior pin They can be hung from a grid with a Junior pipe hanger Junior pin attached to Pole Op Yoke Note Because of weight capacity the MTP I40 can only be used on the ParaBeam 210 Yoke Fixture Warning Use only M5 X 10mm screws supplied to assembl...
Страница 9: ... the bracket by turning the silver thumbscrew Position the Top and Bottom Doors to allow for sufficient movement Hinge tension on Top Bottom Doors is adjusted by tightening the nut Use a screwdriver to adjust the Side Doors Side Doors Top Bottom Doors Hinge Tension Adjustment Warning Do not pull yoke to adjust tilt Turn the white knob counter clockwise to angle the yoke 90 Top Bottom Door Side Doo...
Страница 10: ...el D DMX Address Sets DMX address of Fixture E Dimmer Knob Manual dimming control Warning To Ensure Proper Operation ALWAYS TURN OFF THE FIXTURE BEFORE connecting or disconnecting lamps After the lamps are properly installed the fixture can be turned on Avoid operating in temperatures above 125 F 51 C or below 60 F 15 C In temperatures below 60 F or 15 C the fixture may take longer to strike If la...
Страница 11: ...rop in exposure without shifting the color temperature The MANUAL DIM LAMPS switch selects 4 lamp or 2 lamp operation Select the 2 lamp setting to turn off the outer lamps Note All manual controls are disabled as soon as the DMX cable is applied For manual control with DMX cables plugged in set address to 000 There is a 5 second delay when switching between DMX and Manual control The DMX CHANNELS ...
Страница 12: ...ut wiring follows the USITT DMX512 standard Pin 1 Shield Pin 2 Data Pin 3 Data Pin 4 Spare Pin 5 Spare Note Pin four and five in the Fixture are connected internally as Pin four to four and Pin five to five Connecting Pin four and five as the pass thru allows secondary data to be passed through other equipment Note If a Fixture loses its DMX signal it will hold its last DMX command For this reason...
Страница 13: ...0 seconds and restart Replace ballast card with one that is known to work With DMX cable connected if yellow light is off there is no DMX signal Establish a valid DMX signal With DMX cable plugged in and yellow indicator on 1 Address must be between 001 and 512 Addresses above 512 are invalid 2 The dimmer setting on lighting board must be in the full up mode CHECKING BALLAST Pull out 3 white push ...
Страница 14: ...et of 4 LVR P490 LVR P460 LVR P445 LVR P290 P LVR P260 P LVR P245 MTP I80 Junior Pin Assembly for Yoke 28mm MTP I40 Baby Receiver Assembly for Yoke 16mm ParaBeam 410 Louver 90 ParaBeam 410 Louver 60 ParaBeam 410 Louver 45 ParaBeam 210 Louver HP 90 ParaBeam 210 Louver HP 60 ParaBeam 210 Louver 45 ...
Страница 15: ...10 Yoke Assembly 7010005 ParaBeam 210 Yoke Assembly MTP LB Kino 41 Lollipop w Baby Receiver 16mm 7010006 ParaBeam 410 Pole Op Assembly 7010007 ParaBeam 210 Pole Op Assembly MTP LMT Kino 81 Lollipop w Junior Pin Straight 28mm for Center Mount only MTP LM Kino 81 Lollipop w Junior Pin 28mm ...
Страница 16: ... 75 x 28 x 75cm 31 lb 14kg ParaBeam 410 KAS P21 ParaBeam 210 Center Ship Case 21 5 x 11 5 x 29 54 6 x 29 2 x 73 6cm 26 lb 11 7kg ParaBeam 210 KAS CL6 6 Lamp Carry Case 55W Compact 24 x 7 x 2 5 61 x 18 x 6 5cm 0 8 lb 0 4kg 55W Compact Lamps 6 KAS P41 KAS CL6 True Match Lamps 55C K32 55W Kino KF32 55C K55 55W Kino KF55 ...
Страница 17: ...Mount Input Voltage 120VAC or 230VAC 50 60Hz Output Frequency 30kHz Amperage 2 0A at 120VAC 1 1A at 230VAC Lamp Switching 4 2 Dimming Range 100 5 Weight w lamps 22 5 lbs 10 2kg Dimensions 29 5 x 27 x 6 75 x 68 x 15 2cm Lamp type 55W CFL w 2G11 base Fixture Specifications ParaBeam 410 Pole Op Model PAR 410P ParaBeam 410 DMX Pole Op Input Voltage 120VAC or 230VAC 50 60Hz Output Frequency 30kHz Amper...
Страница 18: ...Beam 210 DMX Yoke Mount Input Voltage 120VAC or 230VAC 50 60Hz Output Frequency 30kHz Amperage 1 1A at 120VAC 0 6A at 230VAC Lamp Switching 2 off Dimming Range 100 5 Weight w lamps 16 lbs 7 3kg Dimensions 29 5 x 16 x 6 75 x 40 x 15 2cm Lamp type 55W CFL w 2G11 base ParaBeam 210 Pole Op Model PAR 210P ParaBeam 210 DMX Pole Op Input Voltage 120VAC or 230VAC 50 60Hz Output Frequency 30kHz Amperage 1 ...
Страница 19: ...19 ...
Страница 20: ...ronic Equipment This symbol on the product or on its packaging indicates that this product shall not be treated as household waste This product is made of recyclable materials and should be disposed of in accordance with governmental regulations Kino Flo Inc 2840 N Hollywood Way Burbank CA 91505 USA Tel 818 767 6528 website www kinoflo com ...