background image

Operation Manual

 

Celeb  200 DMX LED

Part No. 3100065 Rev A                                                                                         09-25-2013

®

 

Содержание CEL-200C-120U

Страница 1: ...Operation Manual Celeb 200 DMX LED Part No 3100065 Rev A 09 25 2013 ...

Страница 2: ...ount Univ 230U CEL 200Y 120U Celeb 200 DMX Yoke Mount Univ 120U CEL 200Y 230U Celeb 200 DMX Yoke Mount Univ 230U CEL 200P 120U Celeb 200 DMX Pole Op Univ 120U CEL 200P 230U Celeb 200 DMX Pole Op Univ 230U LVR CE290 P Celeb 200 Louver HP 90 Included GFR CE2 Celeb 200 Gel Frame Included Celeb 200 Center Mount Celeb 200 Yoke Mount Celeb 200 Pole Op ...

Страница 3: ... KIT C2 120U Celeb 200 DMX Center Mount Kit Univ 120U KIT C2 230U Celeb 200 DMX Center Mount Kit Univ 230U Kit Contents 1 Celeb 200 DMX Center Mount 1 Flight Case Weight 31 lb 14kg Dimensions 29 x 10 5 x 17 74 x 27 x 43cm 3 ...

Страница 4: ...a green light will appear to the left of the button and Dim level is displayed D Display Provides Kelvin Dim level and software revision data E LOCK RESET In LOCK mode an amber light is displayed to the left of the button In RESET mode the indicator light is green To reset to factory presets hold the LOCK RESET button for 5 seconds F On Off On Green light displayed Off Amber light displayed G Data...

Страница 5: ...olarity is Pin 1 Ground Pin 2 18 28VDC Pin 3 not used AC Input The Celeb is powered AC with the built in power supply with universal input from 100 240VAC Note When operating AC attach the Velcro strap around the baby receiver lollipop as a strain relief The handles also provide an attachment point for a safety chain if fixture is hung from a grid Ambient Operating Temperature The Celeb is designe...

Страница 6: ...e 5 Kelvin factory preset buttons Left to right they display 2700K 3200K 4000K 5000K and 5500K A green indicator will light to the left of the active button Rotating the adjustment knob will change the Kelvin Press the rotating knob once to shift the Kelvin profile from Coarse to Fine increments In the Coarse mode the fixture can be adjusted in one rotation of the knob In Fine mode it will require...

Страница 7: ...power is turned off or removed the fixture will remember its last setting Press the KELVIN DIM button The indicator light to the left of the button will turn green Rotating the adjustment knob will dim the light of the fixture Press the rotating knob once to shift the Dim profile from Coarse to Fine increments In the Coarse mode the fixture can be adjusted in one rotation of the knob In Fine mode ...

Страница 8: ...in The indicator light will turn green In LOCK mode you can toggle back and forth on the KELVIN DIM button and review your Kelvin and Dim settings Note When the power is removed the fixture will reset to unlock To reset factory settings press and hold the LOCK RESET button for 5 seconds The indicator light will turn green and the display will flash 5000 and light output will be at 100 Lock Mode Re...

Страница 9: ...and hold the DMX ADDRESS button to select a DMX address The displayed number will flash while in edit mode Turn the dimming knob to select a valid address from 1 512 Note 0 or 513 999 are invalid addresses Press the rotating knob once to shift between Fine single digits and Coarse in 10th s address selection DMX Operation 9 To save the DMX channel press the DMX ADDRESS button again When set the di...

Страница 10: ...ll default to 5500K and dim setting will be at 100 Sliding the fader on the 1st channel will lower the light level Sliding the fader on the 2nd channel will lower the Kelvin from 5500K to 2700K See chart on the following page for approximate Kelvin dimmer levels The fixture may respond 4 slider channels depending on the dimmer board All manual controls are disabled once the DMX cable is applied an...

Страница 11: ...in four and five as the pass thru allows secondary data to be passed through other equipment Do not use Microphone Cables and other general purpose two core cables designed for audio or signaling use They are not suitable for DMX512 Problems due to incorrect cabling may not be immediately apparent Microphone Cables may appear to work fine but systems built with such cables may fail or be prone to ...

Страница 12: ...ounted to pipe grid Lollipops are interchangeable MTP L Kino 41 Lollipop w 3 8 Pin 10mm MTP LB Kino 41 Lollipop w Baby Receiver 16mm MTP LBS Kino 41 Lollipop w Baby Receiver Short 16mm A 180 turn loosens the orientation of the mount A right turn tightens the mount The tension on the lock lever may be adjusted by pulling the handle away from the mount This disengages the handle from the screw mecha...

Страница 13: ... also sold separately Note The yoke also provides an attachment point for a safety chain Warning Use only M5 X 10mm screws supplied to assemble yoke Note that threads on the fixture are self locking and may seem tight Replacement screws Part No 2020127 Recommended torque setting USA 18 lb in Metric 2 Nm Baby Offset Arm The Kino Offset w Baby Receiver MTP B41F allows fixtures to mount on the center...

Страница 14: ...cup alters the Tilt up or down Rope Hang Accessory holders are also designed to enable 4 point rope hangs for specialty rigging applications The Celeb 200 Mount w Pin MTP CE can be used as addi tional mount points for example car rigs etc MTP CE Junior pin attached to Pole Op Yoke Warning Do not pull yoke to adjust tilt Turn the white knob counter clockwise to angle the yoke 90 ParaBeam shown for ...

Страница 15: ...ncludes spring loaded accessory holders and two channels to hold the Gel Frame and Honeycomb Louver Place the long edge of the Gel Frame or Honeycomb Louver into the lower channel Press down on the left and right corners of the Gel Frame or Louver and slip the upper edge into the upper channel of the fixture To remove reverse the procedure Note Do not press down along the top center portion of the...

Страница 16: ...thin the extruded edge BRD CE2 Display Protection Condition Description Normal Condition Cause Solution OCP Over Current Protection Shut down current 2 45A in excess of 20 2 04A 100 dim Repair Service Center OVP Over Voltage Protection Shut down voltage excess 30V Below 28V Wrong Battery or 24V Battery w too high Open Voltage UVP Under Voltage Protection Shut down voltage below 17V Excess 18V Dead...

Страница 17: ...cessories BRD CE2 Celeb 200 Barndoors Set of 4 GFR CE2 Celeb 200 Gel Frame Troubleshooting continued Can t set the DMX address You must Press and Hold the DMX Address button for 3 seconds in order to select an address The display will flash while in edit mode Select a valid address from 1 512 Note 0 or 513 and higher are invalid addresses Can t operate the fixture manually with the DMX cable plugg...

Страница 18: ...se KAS CE2 C Celeb 200 Travel Case KAS CE2 Y Celeb 200 Yoke Ship Case STD M30 Medium Duty Stand Black 30 STD M36 Medium Duty Stand Black 36 7010032 Celeb 200 Yoke Assembly 7010038 Celeb 200 Pole Op Assembly MTP I80 Junior Pin Assembly for Yoke 28mm MTP CE Celeb 200 Mount w Pin ...

Страница 19: ...t Voltage 18 28VDC 100W Amperage VDC 4 0A at 24VDC Kelvin Range 2700K 5500K Dimming Range 100 1 Weight 15 lb 6 8kg Dimensions 24 x 14 x 5 CEL 200Y 120U Celeb 200 DMX Yoke Mount Univ 120U AC Input Voltage 100 240VAC 50 60Hz 100W Amperage VAC 0 96A at 120VAC DC Input Voltage 18 28VDC 100W Amperage VDC 4 0A at 24VDC Kelvin Range 2700K 5500K Dimming Range 100 1 Weight 16 lb 7 3kg Dimensions 28 5 x 16 ...

Страница 20: ...91505 USA Tel 818 767 6528 website www kinoflo com Celeb 200 DMX Pole Op CEL 200P 120U Celeb 200 DMX Pole Op Univ 120U AC Input Voltage 100 240VAC 50 60Hz 100W Amperage VAC 0 96A at 120VAC DC Input Voltage 18 28VDC 100W Amperage VDC 4 0A at 24VDC Kelvin Range 2700K 5500K Dimming Range 100 1 Weight 17 lb 7 7kg Dimensions 29 x 16 5 x 6 74 x 42 x 15 2cm CEL 200P 230U Celeb 200 DMX Pole Op Univ 230U A...