PARTIAL SEALANT RECOVERY
(PSR)
In the partial recovery arrangement, the
pump discharges water and gas into a gas/
liquid separator tank, releasing the gas to the
atmosphere and retaining the water. Some water is
disposed of through an overflow and the remainder
is retained in the separator tank for recirculation.
Makeup water is added in a quantity necessary to
maintain proper sealing water temperature. This
is the most commonly used arrangement where
sealing liquid conservation is required.
The optional system components are described
.
Figure 3-2 – Piping Schematic: Partial Sealant Recovery System