STORAGE 

Store the products in a dry place. Protect from sunlight. Only temporary stor-
age of AdBlue® in the tank is allowed, subject to compliance with local fire 
protection and Health and Safety regulations. 

BlueTruckMaster® should not be stored in temperatures lower than -10°C 
unless the tank and its equipment (esp. pump, flowmeter and nozzle) are 
absolutely empty. Otherwise freezing liquid may damage these elements. 
Prolonged storage of AdBlue® in temperatures higher than 25°C may lead 
to  its  decomposition  or  excessive  evaporation  of 
water from it. This does not influence the tank and 
its equipment. 

After  use  the  pump  power  cord  should  be 
disconnected from the power source and the unit 
lid  should  be  closed.  The  lid  is  shower  proof  and 
protects  the  tank  and  equipment  from  light  and 
moderate rain, but is not water tight. 

With  the  exception  of  BlueTruckMas-
ter® 900, all tanks can be stacked on top 
of one another (up to 3), but only if they 

are empty. Otherwise they can be damaged. 

14.

 

MAINTENANCE 

Keep the tank and its equipment clean and in good condition. Before each 
use, check the product for damages, in particular check whether the struc-
ture  of  the  tank  is  not  affected,  all  connections  are  tight  and  the  pump 
power cord is not damaged. 

Do not use a damaged or poorly marked tank. A dirty tank or its 
equipment may contaminate the stored AdBlue® and as a result 
cause engine damage. 

Содержание BlueTruckMaster 200

Страница 1: ...BlueTruckMaster Mobile tank for distribution and transport of AdBlue Operating and safety manual November 2016 Ver 2...

Страница 2: ......

Страница 3: ...ter use 3 5 Technical specifications 3 6 First use 6 7 Handling 6 8 Transport 7 9 Filling a tank 8 10 Connecting the pump 8 11 Vehicle refuelling 9 12 Flowmeter 9 13 Storage 10 14 Maintenance 10 15 Wa...

Страница 4: ...mental protection The manufacturer is not liable for damages or losses caused by improper use of the product and failure to comply with applicable regulations Store the manual in a safe place for futu...

Страница 5: ...he further parts of this text only AdBlue name is used Using the tank for storage transport or distribution of other liq uids it is prohibited without written permission of the manufac turer Moreover...

Страница 6: ...BlueTruckMaster 300 dimensions W D H 600 800 890 mm nominal capacity 300 L BlueTruckMaster 200 low profile dimensions W D H 1180 860 500 mm nominal capacity 200 L BlueTruckMaster 430 dimensions W D H...

Страница 7: ...n system consists of the following elements they may vary depending on the actual specification of the tank 1 polyethylene tank 2 lid 3 vent 4 inlet 5 hose suction pipe fitted with a mesh filter 6 shu...

Страница 8: ...used in vehicles or discharged into sewage system If the above guidelines are not followed the content of the tank may get contaminated and this can result in damage to the en gine in the vehicle 7 HA...

Страница 9: ...road and EN 12195 which specifies the methods and rules for calculating clamping force Tanks have special features to allow securing of the device to the vehicle by belts Examples are shown in figure...

Страница 10: ...be filled only with AdBlue The maxi mum filling rate is 100 l min and it should not be exceeded Pay attention to the vent and check if it is not blocked when filling a tank 10 CONNECTING THE PUMP Bef...

Страница 11: ...ue tank inlet Refuelling will start within two minutes after pressing the nozzle pushbut ton When handling tanks that are not equipped with automatic fill ing nozzles pay attention to prevent tank ove...

Страница 12: ...uence the tank and its equipment After use the pump power cord should be disconnected from the power source and the unit lid should be closed The lid is shower proof and protects the tank and equipmen...

Страница 13: ...sheet of AdBlue In particular quickly and safely stop or reduce the spill of Ad Blue by sealing a tank or cut of the flow of AdBlue in the case of events occurring during the filling of a tank Dependi...

Страница 14: ...the pump Pump is damaged or blocked Check if the pump is connected to the correct power source Repair or replace the pump Pump is operating but no liquid is fed The tank is empty Ball shut off valve i...