017904-04 BioFicient 4-6 Installation Manual
FAULT FINDING
1.
COMPRESSOR NOT RUNNING
Cause
Remedy
Power cut
Do nothing. When power is restored the system will restart
automatically
Check Mini Circuit Breaker on electrical supply board
Power supply RCD (Residual current
Device) tripped
Isolate the power supply and reset the RCD
Switch on the blower, which should start automatically
If not, switch off the power and call an electrician
2.
NO EVIDENCE OF AIR BUBBLES RISING THROUGH THE MEDIA
Cause
Remedy
Blower not running
Refer to fault condition 1
Contact our Service company (Details on front cover)
3.
MEDIA NOT MOVING
Cause
Remedy
Blower not running
Refer to fault condition 1
Contact Service company
4.
NO BIOMASS GROWTH ON MEDIA OR WHITE GROWTH THROUGHOUT BOTH BIOLOGICAL
REACTORS
Cause
Remedy
Blower not running
Refer to fault condition 1
Contact service company
Toxic input
Consider each chemical and the amount used within the
properties
E.g. washing powders bleaches. Switch to alternative
products, consider switch from biological powders to non
biological washing liquids and use less per wash
5.
SMELL
Cause
Remedy
Blower not running
Refer to fault condition 1
Contact service company
Time for a Desludge
Remove sludge from primary and final compartments