012696 GL0011P-07
– Installation Guidelines for BioDisc BA, BAx, BB & NB Units
Page 13
4.10.5 Turn on the panel using the isolation switch. It should now be illuminated red. The display should now
read “- -“. Press the orange reset button next to the display to clear the display.
4.10.6 Replace the main cover and screws.
4.10.7 The unit is now fully operational.
5
Control Panel Fault Codes & Fuses
All fuses are Time Lag HBC 20mm type.
6
Ancillary Equipment
6.1.1
Ancillary items should be installed in accordance with the Installation Guide supplied e.g. Crude
Sewage Pump Station /Effluent Pump Station/Effluent Sample Chamber.
7
Start Up
7.1.1
We recommend that the unit has a Pre-Service Agreement Inspection by an approved engineer.
7.1.2
Refer to the Owners Handbook for details of the Start Up Procedure.
7.1.3
Once the unit has been installed it should be left filled with water. Please switch on the motor,
following the procedure in the Owners Handbook and leave the unit running, even if there is no
sewage being fed into the plant.
7.1.4
If the unit has been installed with no operational power supply, then remove the
motor/gearbox unit and store it in a dry or heated environment until such time as the unit is
ready for permanent operation.
7.1.5
DO NOT CONNECT UNITS WITH INTEGRAL PUMPS TO A SEWAGE SUPPLY, WITHOUT
ENSURING THAT THE ELECTRICITY IS CONNECTED AND THAT THE UNIT IS OPERATIONAL
(IF THE MOTOR AND GEARBOX IS FLOODED, REPLACEMENTS WILL BE REQUIRED)
CODE
FAULT CONDITION
FUSE
Amp
F1
No power to the unit
Customer
Fuse box
N/A
F2
The blower pressure has failed (PPFDS kit required)
N/A
N/A
F3
The high level alarm has activated (where fitted)
N/A
N/A
F4
The fuse to the blower/motor has failed
F3
3.15
F5
The fuse to the discharge pump (where fitted) has failed
F1
5.0
F6
The fuse to the chemical dosing pump has failed
F4
0.25
F7
The fuse to the recirculation pump has failed
F2
5.0
F8
The loss of rotation alarm has been activated
N/A
N/A
--
The unit has had a fault which has now corrected itself
N/A
N/A