background image

IMPORTANT:

This product should be installed by a 

competent person and in accordance with 

the IET Wiring Regulations. 

If in doubt, consult a qualified electrician. 

These instructions should be read carefully

prior to any installation and retained after

completion for further reference and

maintenance.  Please give these 

instructions to the building owner/occupier

after installation.

Always turn off the power source before

commencing work on this device.

Part numbers: 

LEDFL

10

, LEDFL

20

, LEDFL

30, LEDFL50,

LEDFL80, LEDFL120 & LEDFL150

Installation / Operating

Instructions for 

IP65 LED Floodlight Fittings 

IMPORTANT INFORMATION

INSTALLATION INSTRUCTIONS

This luminaire is water resistant to IP

65

but

it is advisable, wherever possible, to locate it

in a sheltered location. No modification

should be made to the casing to preserve the

moisture properties and warranty. 

This fitting is supplied pre-wired with 

0.9

M

of three core cable (Live, Neutral and Earth).

This cable can 

NOT

be removed. Connection

must be made via a suitable terminal box.

Should the flex become damaged it should

be replaced with cable of the same 

specification and only by a competent 

person. To avoid a heat build up it is 

advisable that a clear air gap is left around

the luminaire and the front face should be at

least 

500

mm away from any combustible 

surface. The supplied bracket should be used

at all times for mounting. 

TECHNICAL INFORMATION

This appliance is designed to work with a

mains voltage of 

100

V to 

250

V AC 

50

Hz.

It should be wired to an appropriately fused

and protected source.

Lumen Output: 

10

W

700

lm

20

W

1400

lm

30

W

2100

lm

50

W

3500

lm

80

W

5600

lm

120

W

9000

lm

150

W

10500

lm

LEDFL10 20 30 50 80 120 150 Ins.qxp_MR16  11/02/2016  12:   

 

Отзывы: