It is 

ALWAYS

 recommended to order your unit with or without the thermostat for your particular application. If your unit 

has been ordered incorrectly please contact the factory and we can exchange it for the proper unit. Adding a built-in 

thermostat after installation is complicated and could result in creating wiring errors and shorting out this unit.

Instructions for wall mount heater

It is

 extremely important

 to verify the electrical power supply is the same voltage as the heater you are installing. 

240 and 

120 Volt heaters are not interchangeable.

 Powering a 240 Volt unit with 120 Volt supply wires will reduce the heater's output 

by approximately 75%. Powering a 120 Volt unit with 240 Volt supply wires will destroy the heater and voids all warranties.

NOTICE

: For heaters without built-in thermostats - using remote or wall mounted thermostats. The power 

must

 be brought to 

the heater first (not to the wall mounted or remote thermostat). This is necessary to provide power for the fan to cool down the 
element after the thermostat has opened. Use only a single pole line voltage wall thermostat or switch to control this heater.

CAUTION: Disconnect the circuit breaker supplying the heater before attempting installation, maintenance, or repairs. 
Lock or tag circuit breaker panel door. Failure to do so could result in serious electrical shock, burns, or possible 
death.

1.  Remove heater contents from carton and check for 
 

shipping damage.

2.  Remove grill by loosening the four mounting screws along the  
 

sides of the front panel.

3.  Detach interior assembly from the wall can by removing the four  
 

screws along each side of the interior panel. Lift and tilt assembly

  

away from the top of the wall can. Free the bottom edge from the  

 

metal lip inside the wall can. Place the interior assembly in a safe  

 

location until the wall can is mounted.

4.  Remove one knockout from the wall can and thread supply wires  
 

through the hole. Use an approved cable connector to prevent  

 

wires from chafing. Connect groundwire to green pigtail.  

5.  Mount heater wall can on wall studs a minimum of 6" from  side  
 

wall and 10" from floor, using the holes provided in the sides of  

 

the box. The face of the box should be flush with the finished  

 

wall. Installation of the interior and grill to the wallbox cover an

 

approximate 5/8" periphery along the outer area of the opening.  

6.  After wall can is secured interior assembly leads may be attached supply wires  
 

and interior secured to wall can. 

NOTE: 

The LPW wall heater is equipped with  

 

two steel elements having a combined capacity of 2750 Watts. The heater is   

 

factory wired at 2750 Watts. To adjust the heater for lower wattages remove   

 

the appropriate colored wire according to the illustration and wattage diagram

 

provided on the back side of this sheet. Be sure to insulate and secure the    

 

unused lead.

7.  Reinstall interior assembly on wallbox using screws provided.

8.  Mount grill to interior with screws provided.  

LPW1227 120 VOLT MODEL

Maintenance & Warranty

The high quality and superior design of this unit will enable years of maintenance-free performance. Once yearly 

the heater should be checked for lint or dust accumulation but no further maintenance is required. The motor is 

permanently lubricated and sealed. A five year warranty is provided on the Pic-A-Watt

®

 element and 1 year on all 

materials, components and workmanship.

VISUAL ALARM

This heater includes a visual alarm to warn that 
parts of the heater are getting excessively hot.  
If the alarm flashes immediately turn the heater 
off and inspect for any objects on or adjacent to 
the heater that may cause high temperatures.  

Do  not  operate  the  heater  with  the  alarm 
flashing.

LPW1227.indd : 4/08

FAN-FORCED 

HEATERS:

Clearances for Safe 
Operation