D
OCUMENT
301900,
R
EVISION
D
E
PI
S
ENSOR
U
SER
G
UIDE
23
Table 2: Range/sensitivity calculations
Full-scale
range
Single-ended
"
2.5V output
Single-ended
"
10V output
Differential
"
5V output
Differential
"
20V output
1/4g
10 V/g
40 V/g
20 V/g
80 V/g
1/2g
5 V/g
20 V/g
10 V/g
40 V/g
1g
2.5 V/g
10 V/g
5 V/g
20 V/g
2g
1.25 V/g
5 V/g
2.5 V/g
10 V/g
4g
0.625 V/g
2.5 V/g
1.25 V/g
5 V/g
Voltage values stated are as measured across each channel’s output pins.
L-M, A-B, C-D for axes X, Y, and Z respectively. Pins L, A, and C are (+)
and pins M, B, and D are either (-) or ground depending on whether
configured for a differential or single-ended connection to the recorder.
For best performance, a differential connection to the recorder should be
used if the recorder supports differential input connections.
Figure 13: Feedback board
X1
X4