CONTENTS
PAGE
Section 1
Information and Requirements
1.0
Appliance information
3
1.1
Conditions of installation
4
1.2
Fireplace surround & suitability
4
1.3
Flue terminal position
5
1.4
Shelf position
6
1.5
Hearths
6
1.6
Installation to plastered wall surfaces
6
Section 2
Installation of Fire
2.1
Unpacking the combustion chamber
7
2.2
Preparing the combustion chamber opening (In studded wall)
8
2.3
Preparing the combustion chamber opening (In chimney breast)
9-10
2.4
Installation of the gas supply
11
2.5
Specifying the flue system & components
12-14
2.6
Preparation of the wall
14
2.7
Preparation of the flue hole
15
2.8
Fitting the starter pipe
15-16
2.9
Fitting the flue pipes together
17
2.10
Fitting the flue terminal
18
2.11
Fitting the flue terminal guard
19
2.12
Removal & re-fitting of the glass frame
20
Section 3
Assembling Fuel Bed and Commissioning
3.1
Fitting the fuel bed logset
21-25
3.2
Making the gas conection & checking for gas tightness
26
3.3
Lighting the appliance
26-28
3.4
Removal & re-fitting the trim
29
Section 4
Maintenance
4.1
Removal of the burner assembly
30
4.2
Removal of the control valve
30-31
4.3
Removal of the ultrasonic reciever
31
4.4
Removal of the pilot assembly
31-32
4.5
Removal / Replacement of batteries in the Ultrasonic Receiver
32
4.6
Removal / Replacement of the handset battery
32
Model number KBFL**RN2
manufactured by:-
BFM Europe Ltd, Trentham Lakes, Stoke-on-Trent, Staffordshire, ST4 4TJ
Appliance Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS EN 613 : 2001 and the result is 74%. The gross calorific value of the fuel has
been used for this efficiency calculation. The test data from which it has been
calculated has been certified by GL Industrial Services UK Ltd. The efficiency
value may be used in the UK Government’s Standard Assessment Procedure
(SAP) for energy rating of dwellings.
2