background image

c)

Fit five of the large sized coals onto the front ceramic rail, ensuring

that they are evenly spaced. Use the recess’s in the front ceramic rail

as a guide for placement. (See fig. 12 below)

Fig. 12

d)

Select four of the large coals and arrange behind the front row of coals,

ensuring that flame paths as indicated below are not interupted.

.

(See fig. 13 below)

Fig. 13

19

Содержание Black Magic

Страница 1: ...Magic DECORATIVE FUEL EFFECT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No KRDCD0MN is for use on Natural Gas G20 at a supply pressure of 20 mbar in G...

Страница 2: ...stem 9 Section 2 Installation of Fire 2 1 Unpacking the fire 10 2 2 Installing the fire box 10 2 3 Gas tightness and inlet pressure 16 Section 3 Assembling Fuel Bed and Commissioning 3 1 Assembling th...

Страница 3: ...fitted Width with trim no spacer 520mm Height with trim no spacer 610mm Depth from mounting face to rear panel without spacer fitted 170mm Efficiency Declaration The efficiency of this appliance has b...

Страница 4: ...and Terminals 8 I S 813 1996 Domestic Gas Installation Republic of Ireland In Repuplic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B...

Страница 5: ...150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check that the chimney flue only ser...

Страница 6: ...ied out during commissioning of the appliance 1 6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fire place must be between 375 and 440 mm wide and between 550 and 570mm high...

Страница 7: ...use in fireplaces fitted with an existing chairbrick without the need for removal of the chairbrick providing the minimum depth of the fireplace exceeds 260mm If the depth is less than 260mm then the...

Страница 8: ...n accordance with BS EN 1858 pre cast flues built with directly plastered faces front or rear are not correctly installed as to ensure proper operation with any type of gas fire In some instances of t...

Страница 9: ...h the fire is operated The following are important warnings relating to this spillage monitoring system 1 The spillage monitoring system must not be adjusted by the installer 2 The spillage monitoring...

Страница 10: ...ook 2 2 INSTALLING THE FIRE BOX Establish which type of flue you are intending to install the fire in to 225 x 225mm 9 inch x 9 inch brick built chimneys 175mm 7 inch diameter lined brick or stone flu...

Страница 11: ...ge and carefully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps presen...

Страница 12: ...n to the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 5a 5b below for suggested concealed pipe layouts Fig 5...

Страница 13: ...which in turn will damage the burner and control systems of the product Fig 6 below shows a correctly sealed installation Fig 6 PLEASE NOTE 13 BFM EUROPE LTD WILL NOT BE LIABLE FOR GUARANTEE CLAIMS T...

Страница 14: ...round the perimeter of the firebox in a goalpost arrangement to ensure a seal is achieved to the fireplace To fit using the preferred cable method proceed as follows e Mark out and drill 4 off No 14 7...

Страница 15: ...nut i Fit a screwed nipple on to each of the cables and pull hand tight up against the tensioning screw then secure each nipple with a flat bladed screwdriver See fig 8 below Fig 8 j Evenly tighten th...

Страница 16: ...aused to the gas control valve on the fire The other firebox fixing method is as follows In installations where the cable method is not suitable e g loose masonary in rear of fire opening the firebox...

Страница 17: ...ol knob for a few seconds to purge the pipe work then press the igniter button The burner should light continue to hold the control knob for a few seconds then turn to the full on position d Check tha...

Страница 18: ...t and is not lodged on the burner See fig 10 below Fig 10 b Position the two halves of the front ceramic L H R H on the locating channel in the front ceramic ensuring it is located onto the lip on the...

Страница 19: ...hey are evenly spaced Use the recess s in the front ceramic rail as a guide for placement See fig 12 below Fig 12 d Select four of the large coals and arrange behind the front row of coals ensuring th...

Страница 20: ...along the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 14 below Fig 14 f Select the two small coals and position to fill the gaps at each end of the...

Страница 21: ...e articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working o...

Страница 22: ...he pilot position the main burner will go out but the pilot will remain lit g Slightly depress the control knob and turn to the off position the pilot will now be extinguished WARNING If the fire goes...

Страница 23: ...ith the fan running on maximum and all interconnecting doors open f After ensuring that the fire is safe to use it should be left on high position to fully warm up During this time a slight odour may...

Страница 24: ...location Remove the loose coals from the fuel bed and front ceramic rail Remove the front ceramic from the rail Unscrew the two pozi driv fixing screws which secure the burner heat shield and remove i...

Страница 25: ...e Oxy Pilot Assembly Note Because this appliance is fitted with an atmosphere sensing Oxy Pilot it is not possible to replace the thermocouple separately because the thermocouple position is factory s...

Страница 26: ......

Страница 27: ......

Страница 28: ...et B 56340 L H Fibre Board B 56200 R H Fibre Board B 56210 Upper Rear Fibre Board B 56230 Lower Rear Fibre Board B 56220 Piezo Igniter B 1320 Ignition Wire B 39030 Manual Gas Valve NG B 102880 Due to...

Отзывы: