Kinco-HP
User Manual
53
ST
%SM201.4
3.2.5.2
Can it change maximum output frequency when position
control instruction is executing?
PREL
(
Relative position
)
and PABS
(
Absolute position
)
will not change maximum output
frequency when it is executing. It will read the parameters minimum frequency, maximum
frequency and acceleration/deceleration time parameters when it starts, and calculates suitable
acceleration/deceleration segments according to the value of these parameters, then it will start
outputting pulse. During pulse outputting, PREL and PABS will not read the parameters above
again, therefore, changing these parameters will not affect the pulse output.
PJOG
(
Jogging
)
will read pulse input frequency(MAXF) all the time when it is executing, and
adjust the pulse output frequency according to new setting frequency.
PHOME
(
Homing
)
will read the maximum frequency (MAXF) all the time when it is running
at maximum frequency but hasn’t found homing signal, and calculate acceleration or
deceleration segment automatically according the new setting frequency, then it will accelerate
or decelerate to new frequency to output pulse.
Содержание HP043-20DT
Страница 8: ...Kinco HP User Manual 8 1 4 4 Dimension Dimension 132 102 40 1mm Cutout size 119 93mm...
Страница 22: ...Kinco HP User Manual 22...
Страница 23: ...Kinco HP User Manual 23...
Страница 25: ...Kinco HP User Manual 25...
Страница 26: ...Kinco HP User Manual 26 2 It will show settings when mouse at the right side of Window then click settings...
Страница 27: ...Kinco HP User Manual 27 3 Click update and recovery in the PC settings...
Страница 28: ...Kinco HP User Manual 28 4 Click restart now at advanced startup 5 Click advanced options...
Страница 29: ...Kinco HP User Manual 29 6 click startup settings 7 Click restart...
Страница 31: ...Kinco HP User Manual 31 10 Figure as below after successful...