Kinco FD5
系列伺服驱动器使用手册
第五章
KincoServo
上位机使用指南
72
bit
2
:
1
—
use mask
(
23000E20
),
AND gate
Note: You can no longer use the up
and down arrows on the oscilloscope
page to set the trigger edge to
prevent conflicts.
2300.12
Uint32
Trigger source
Oscilloscope Trigger Object
Dec
2300.13
Int32
Trigger level
Oscilloscope Trigger level
Dec
5.7
Error display and error history
Error
:
C
lick“
C
ontroller”
->
“
E
rror display”,
or click
button
(
which turns red
if an
error occurs
),
The Error Display window appears. It shows the last errors.
Figure
5-14 Error
display window
Error history
:
C
lick“
C
ontroller”
->
“
E
rror history”,
The error history window will pop up and
display the last 8 error messages, including error word, bus voltage, speed, current, temperature,
working mode, and power tube status. The most recent historical failure is displayed on the first
line.
Figure
5-15
error history display window