Kinco FD5
系列伺服驱动器使用手册
第四章
数字面板操作
48
Table
4-2 Easy
menu parameters
LED
Parameter
Description
Default
EA01
Motor type
For a new factory drive, the motor model is 00, and the digital panel
displays 3030. If the drive is connected to the correct motor, the motor
model will be automatically recognized and saved by the drive. If there is
no motor model in the drive, the digital panel will flash FFFF.
For the drive that has been used, the drive will judge whether the
connected motor is the same as the previous one.
If they are not the same, the digital panel will flash and display the
FFFF/400.2 fault.
404b
EA02
Command type
The command type affects controller-internal interface setting , the initial
operation mode after power on and the default setting for DIN- and
OUT functions (refer to table 4-3)
0: CW/CCW pulse train mode operation mode=-4
1: P/D pulse train mode operation mode=-4
2: A/B phase control master/slave mode operation mode=-4
6: Analog velocity mode by AIN1 operation mode=-3
7: Analog velocity mode by AIN2 operation mode=-3
8: Communication
9: Position flow mode operation mode= 1
1
EA03
Gear Factor
Numerator
Used when EA02 is set to 0-2
By default, the display shows the values in decimal format. If the number is
greater than 9999, the display is in hexadecimal format
1000
EA04
Gear Factor
Denominator
1000
EA06
1. load
type
2.applicati
on
3. limit
switch
4. alarm
output
polarity
The meaning of each digit of the LED display from right to left.
(1) Load type, influences the control loop.
0: No load
1: Belt drive
2: Ball screw
(2) Application, influences the control loop.
0: P2P
1: CNC
2: Master / slave mode
(3) Limit switch.
0: Controller default
1: Delete the limit switch function
(4) Polarity of OUT5
0: Normally closed contacts
1: Normally open contacts
1001
EA07
Homing method Refer to chapter 6.6