Kinco FD5
系列伺服驱动器使用手册
附录二
常用对象参数列表
202
Other parameter
Name
CANopen
modbus
Commend
type
Data type
Description
Use
internal
motor
library
30410608
-
RWS
Unsigned8
0: Automatically read the
motor model from the
encoder and use the
corresponding motor
parameters in the drive
motor library (factory
default)
1: Support the user to manually
input the motor model and use
the motor parameters
corresponding to the motor
library in the driver
Device
restart
2FFF0010
2F00
RW
Unsigned16
Turn on bootloader
55AA: turn on
bootloader
AA55
:
Drive restart
Analog
Increme
nt
64101F10
-
RW
Integer16
It is used to set the resolution of the
communication
magnetoelectric
encoder to the incremental encoder
resolution, the settable values are
4000, 8000 and 10000
=0: Do not simulate incremental
encoder,
use
default
motor
resolution
>0: Resolution of the simulated
incremental encoder
Содержание FD425-CA-000
Страница 1: ...Manual Kinco FD5 series AC servo system Kinco Electric shenzhen Ltd www kinco cn...
Страница 87: ...Kinco FD5 84 2 Analog speed control 250207 is 0 close the analog speed channel...
Страница 196: ...Kinco FD5 193 Output filter 60F90508 6350 RW Unsigned8 velocity output filter of velocity loop BW Speed_Fb_N 20 100 H z...