Kinco FD5
系列伺服驱动器使用手册
第七章
性能调节
140
Alarm code numbers flash at the panel when the controller generates an alarm.
If you need more detailed information about errors and error history, please connect the
controller to the PC via RS232 and refer to chapter 5.7.
Table 8-1: Alarm codes of Error_State1
Alarm
Name
Reason
Troubleshooting
FFF.F
Wrong
motor
model
The current motor type is different from
the motor type which is saved in the
controller.
Method 1: Access EA01 via the KEY, and
confirm motor type, then access EA00, set
2. Method2: Access EASY_MT_TYPE
(0x304101) via PC software, confirm the
value, then save the parameter.
000.1
Extended Error
Errors occurs
in Error_State2
Press the SET key to enter Error_State2
(d1.16), read the error bit, check the error
meaning in table 8-2.
000.2
Encoder
not
connected
The encoder wiring is incorrect or
disconnected.
Use a multimeter to check connection of
the encoder signal cable
000.4
Encode
r
internal
Internal encoder erroror the encoder is
damaged.
1.
Access panel address d3.51 Encoder_OP
by KEY and set 1.
2.
Try to reset the controller error. If
error persists, replace the motor.
000.8
Encoder CRC
Encoder CRC error
Make sure the equipment is well grounded
001.0
Controller
Temperatur
e
The temperature of
controller’s
power
module has reached the alarm value.
Improve the cooling environment of
the controller.
002.0
Overvoltage
Supply power voltage exceeds the
allowable input voltage range
In case of emergency stop, there is no
external braking resistor or braking.
Check to see if supply power voltage is
unstable and if a suitable braking resistor
is connected.
004.0
Undervoltage
The power voltage input is lower than
the low voltage protection alarm value.
Check to see if supply power voltage is
unstable.
008.0
Overcurrent
Instantaneous current exceeds
the overcurrent protection
value.
Check the motor cable for short circuits.
Replace the controller.
010.0
Chop Resistor
The braking resistor is overloaded or
it’s
parameters are not set correctly.
Set the resistance and power of the
external braking resistor through d5.04
and d5.05.
Содержание FD425-CA-000
Страница 1: ...Manual Kinco FD5 series AC servo system Kinco Electric shenzhen Ltd www kinco cn...
Страница 87: ...Kinco FD5 84 2 Analog speed control 250207 is 0 close the analog speed channel...
Страница 196: ...Kinco FD5 193 Output filter 60F90508 6350 RW Unsigned8 velocity output filter of velocity loop BW Speed_Fb_N 20 100 H z...