Kinco FD5
系列伺服驱动器使用手册
第六章
工作模式介绍
122
Option 2: Purchase
ENCDG-(4)- GU-BT5
cable plus BAT-FD5
battery box accessory,
the battery box can be
installed and fixed on
the bottom of the
drive.
When the battery voltage is lower than 3.1V, the drive will display the warning status word
0001, and the panel will flash 000.1, but the drive will not alarm and stop at this time. Under
the condition that the drive remains powered on normally and the encoder cable is well
connected, replacing the battery will not cause loss of multi-turn data.
When the battery voltage is lower than 2.5V, the drive has an encoder UVW fault or an internal
fault (fault code 000.4), the motor stops running, and the multi-turn data is lost. It is necessary
to replace the battery and re-initialize and configure the absolute encoder.