Kinco FD5
系列伺服驱动器使用手册
第六章
工作模式介绍
100
Figure
6-6
Master slave wiring
6.6
Full closed loop mode
The servo drive is connected to the encoder/grating ruler feedback signal at the mechanical end for
more accurate closed-loop control, which avoids positioning errors due to the mechanical system.
Grating ruler signal
Motor
Motor encoder signal
Machine
Figure
6-7 Full Closed Loop Application Case
Attention
Forward rotation means positive position counting, the default is CCW direction,
you can set the speed position direction control (607E.00) = 1, change the rotation
direction of the motor shaft
Содержание FD425-CA-000
Страница 1: ...Manual Kinco FD5 series AC servo system Kinco Electric shenzhen Ltd www kinco cn...
Страница 87: ...Kinco FD5 84 2 Analog speed control 250207 is 0 close the analog speed channel...
Страница 196: ...Kinco FD5 193 Output filter 60F90508 6350 RW Unsigned8 velocity output filter of velocity loop BW Speed_Fb_N 20 100 H z...
Страница 206: ...Kinco FD5 203...