Kimo LV 110 Скачать руководство пользователя страница 1

PERFORM A MEASUREMENT

Turn on the de device by pressing on 

“On/Off/Esc”

.

The device displays its name 

LV110”

LV111”

 or 

LV117”

.

Put the probe to the required location.

The device displays the velocity and temperature measurement.

Vane probe thermo-anemometer

LV 110 – LV 111 – LV 117 

DESCRIPTION OF THE DEVICE

OK key

Hold/min/max key

Select key

Backlight key

On/Off/Esc key

FREEZE THE MEASUREMENT

During a measurement:

Press once on 

“Hold/min/max”

.

Hold”

 appears on screen and the measurement is frozen.

Press on 

“On/Off/Esc”

 to exit the hold function.

The device returns to the measurement display.

DISPLAY THE MINIMUM AND THE MAXIMUM

Once the measurement is frozen:

Press on 

“Hold/min/max”

The device displays the maximum value of velocity or airflow measured since the last questioning at the top of the screen and the minimum 
value of velocity or airflow measured since the last questioning at the bottom of the screen.

Press again on 

“Hold/min/max”

.

The device displays the maximum value of temperature measured since the last questioning at the top of the screen and the minimum value of 
temperature measured since the last questioning at the bottom of the screen.

Press on 

“On/Off/Esc”

 to return to the measurements display.

Содержание LV 110

Страница 1: ...ff Esc to exit the hold function The device returns to the measurement display DISPLAY THE MINIMUM AND THE MAXIMUM Once the measurement is frozen Press on Hold min max The device displays the maximum value of velocity or airflow measured since the last questioning at the top of the screen and the minimum value of velocity or airflow measured since the last questioning at the bottom of the screen P...

Страница 2: ...and the first digit blinks Press on Select to select its value then press on OK to validate Perform the same procedure to select the values of the following digits to return to the previous digit press on On Off Esc When the last digit is adjusted press on OK to validate The device returns to the display of airflow and temperature measurements If the type of selected duct is rectangular LENGT disp...

Страница 3: ...required unit appears m3 h L s cfm or m3 s Press on OK to validate the unit selection UNIT blinks on screen Press on On Off Esc to return to the measurements display On Off Esc Select 0 L s 25 4 C UNIT SEL m3 h L s OK SEL UNIT L s UNIT SEL m3 h OK SEL UNIT m3 h UNIT SEL C Select OK On Off Esc OK SEL UNIT C UNIT SEL C F SEL UNIT F 0 00 m s 77 3 F Select the measuring unit in velocity The device is ...

Страница 4: ...0 00 m s 25 4 C OK SEL BEEP OFF Adjust the auto shut off The device is on and displays the measurement Press on Select until AUTO OFF blinks on screen Press on OK The time before device auto shut off blinks at the bottom of the screen Press on Select until the required time before auto shut off appears 15 30 45 60 75 90 105 120 minutes or OFF Press on OK to validate AUTO OFF blinks on screen Press...