Part No. 95512
Revision
10/14/11
EC 111014007 Status 22
INSTRUCTIONS PERTAINING TO A RISK OF INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: To reduce the risk of FIRE OR INJURY TO PERSONS: Do Not overdrive fixtures with greater
than12 volts or fixture over-heating and short lamp life will occur. Do Not overload the transformer by
installing (or relamping) higher wattage lamps than planned. Note: Total wattage of all lamps connected to one
transformer must not exceed the capacity of that transformer. Do Not install luminaire within 10 feet (3.04m) of a
pool, spa, or fountain. DO NOT operate luminaire with missing or damaged lens.
SAFETY WARNING: When relamping be sure electrical supply is OFF. Low voltage fixtures can become
very HOT depending on the lamp wattage used. Glass lenses and metal areas above & around the lamp
can become HOT enough to blister hands. Use discretion when touching fixture and be sure to allow fixture to
cool before relamping. When relamping fixture avoid touching the lamp with bare hands. Lighted lamp is HOT!
If touching the lamp is necessary during installation, clean the envelope with alcohol and dry with a clean, soft
cloth before turning ON. Contamination of the envelope may reduce the lamp performance.
MAINTENANCE: To maintain light efficiency and prevent fixture-overheating, glass lenses and enclosure must
be kept clean and free from dirt, dust, leaves, trash (combustible materials) and mineral deposits from water.
Particular care should be taken not to locate fixtures where small children can reach them if higher wattage's are
used. Do not operate luminaire with missing or damaged lens.
Note: Keep the lamp free from impact while burning, as this may deform the filament and shorten the lamp life.
NOT INTENDED FOR INDOOR USE. All electrical work should be done by a qualified electrician.
P.O. Box 60080
•
16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666
•
FAX 626/330-3861
Micro-Flood
®
- KLV215/216/217
Installation Instructions
KLV215
KLV216
KLV217
Tools Required:
F
" Hex Wrench
Phillips Screwdriver
B
" Allen Wrench
Adjustable Wrench
2. Attach fixture unto coupling.
Connect fixture cable to
main system cable with a
KLV410 Sealed Connector
(Part No. 95484).
Make certain electrical supply is
OFF
before starting fixture installation.
!
1. Attach coupling onto mounting
device. (See KLV Mounting
Options, part no. 95488.)
Note:
Kim KLV Mounting
Options can be installed before
fixture is attached.
3. To install lamp, loosen the two (2) captive screws
on lens frame. Install lamp of type and wattage
shown on fixture label and chart on page 2.
Replace lens frame assembly making sure
gasket fits into the recess properly. Tighten
opposing screws progressively & evenly.
(Step 3 not required on L.E.D. version, for L.E.D.
fixture skip to step 4).
Captive Screws
!
Do not overload the transformer by installing (or
relamping) higher wattage lamps than planned.
Remember,
the total wattage of all lamps
connected to one transformer must not
exceed the capacity of that transformer.
90°
*
*
*
Note:
Swivel stem must be installed with the
mounting threads facing down-to
horizontal. Fixtures may not be installed
with mounting threads facing upward
unless shielded from rain or sprinklers.
!
Unit intended for mounting with Diffuser/Glass Barrier and Lamp Holder greater than 2 in. (5.08 cm)
from the ground plane.