Accent Light - KLV205
Installation Instructions
P.O. Box 60080
•
16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666
•
FAX 626/330-3861
INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: To reduce the risk of FIRE, or INJURY TO PERSONS: Do not overdrive fixtures with greater
than 12 volts or fixture over-heating and short lamp life will occur. Do not overload the transformer by
installing (or relamping) higher wattage lamps than planned. Note: Total wattage of all lamps connected to one
transformer must not exceed the capacity of that transformer. Do not install luminaire within 10 feet (3.04m) of a
pool, spa, or fountain. DO NOT operate luminaire with missing or damaged lens.
SAFETY WARNING: When relamping, be sure electrical supply is OFF. Low voltage fixtures can become
very HOT depending on the lamp wattage used. Glass lenses and metal areas above & around the lamp
can become HOT enough to blister hands. Use discretion when touching fixture and be sure to allow fixture to
cool before relamping. When relamping fixture avoid touching the lamp envelope with bare hands. If touching
the lamp is necessary during installation, clean the envelope with alcohol and dry with a clean, soft cloth before
turning ON. Contamination of the envelope may reduce lamp performance.
MAINTENANCE: To maintain light efficiency and prevent fixture-overheating, glass lenses and enclosure must
be kept clean and free of dirt, dust, leaves, trash (combustible materials) and mineral deposits from water.
Particular care should be taken not to locate fixtures where small children can reach them if higher wattage's are
used.
Note: Keep the lamp free from impact while burning, as this may deform the filament and shorten the lamp life.
N
Unit intended for mounting with Diffuser/Glass Barrier and Lamp Holder greater than 2 in. (5.08 cm)
from the ground plane.
OT INTENDED FOR INDOOR USE. All electrical work should be done by a qualified electrician.
KEEP THIS SHEET FOR FUTURE REFERENCE.
Part No. 95489
EC 111014007 Status 18
Tools Required
:
F
” Allen Wrench
Flat Blade Screwdriver
Adjustable Wrench
B
" Allen Wrench
Philips Screwdriver
!
4. To install lamp, remove four shield
screws.
KLV205
Shield
Lens Gasket
Assembly
Screws
Drain Hole
1. Remove coupling from fixture.
2. Tighten coupling onto
mounting device.
5. Remove shield and lens gasket
assembly.
3. Install fixture onto coupling. Attach fixture
leads.
Note:
KIM KLV Mounting Options can
be installed before fixture is attached.
!
IMPORTANT!
DO NOT
overload the transformer by
installing (or relamping) higher
wattage lamps than planned.
Remember, the total wattage of all
lamps connected to one trans-former
must not exceed the capacity of that
transformer.
6. Install lamp of type and wattage
shown on fixture label and chart on
page 2.
Installation Instructions
:
Make certain the electrical supply is
OFF
before starting fixture installation.
!
Revision