HA31 - Ribbon Arm Wall Mount with Top Scroll
Installation Instructions
P.O. Box 60080 • 16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666 • FAX 626/330-3861
Revision
7
/
16
/10 EC 100715008 Status 3 Part No. 95712
Tools Required
:
Flat Head Screwdriver
Torque Wrench
F
" Hex Wrench
3/32
" Hex Wrench
5/32
" Hex Wrench
Sealant
RA17, AE17, BE17, LE19:
N
" 6- or 12- Point Deep (2" min.) Socket
12" (min.) Long Socket Extension
RA25, AE21, BE21, LE26:
L
" 6- or 12- Point Deep (2" min.) Socket
20" (min.) Long Socket Extension
WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code.
Failure to do so may result in serious personal injury.
MAINTENANCE: A regularly scheduled maintenance program must be established to insure paint coating is
intact, corrosion or structural damage has not occurred, and all mounting arms, rods, nuts and bolts are tight.
Failure to do so could lead to danger or serious personal injury.
CAUTION: Structural integrity of mounting plate attachment to wall is by others.
KEEP THIS SHEET FOR FUTURE REFERENCE.
Make certain electrical supply is
OFF
before starting installation.
1. Remove wiring inspection cover
from wall plate and wall mount
cover plate. Adhere rope caulk in a
continuous strip into the wall plate
groove. Allow caulk to extend well
above the wall plate surface to
ensure a proper seal.
2. Securely mount wall plate over
junction box (by others).
CAUTION: Structural integrity
of mounting plate attachment to
wall is by others.
!
4. Attach fixture to arm fitter. (See
fixture installation instructions.)
3. Insert arm bolts into wall mount
cover.
Junction Box
(By Others)
Wall Mount
Cover
Arm Fitter
Wall Plate
Groove
5. Install ribbon arm onto wall plate
cover.
Ribbon
Arm
6. Pull fixture wires through arm fitter,
ribbon arm and wall plate cover.
Install arm fitter with fixture head to
ribbon arm using a torque wrench.
Fixture Wires
!
RA17, AE17, BE17, LE19
RA25, AE21, BE21, LE26