56
PWX
Preset Memory Function
Recalling preset memory entries
You can recall preset memory entries from the measured value display (when the SET key
LED is off) and from the setting display (when the SET key LED is lit).
If the output is on, the values in the preset memory entry are applied to the output the
moment that the preset memory entry is recalled (the moment that the settings are applied).
p. 46
There are two methods to recall a preset memory entry. One method is to display the saved
contents for confirmation and then recall (CF04: on). The other is to recall immediately with-
out displaying the contents (CF04: oFF).
When you recall a preset memory entry, the following items are set to their factory default set-
tings.
p. 46 , p. 47 , p. 48
• Constant current control using an Vext or Rext (CF05: oFF)
• Constant voltage control using an Vext or Rext (CF06: oFF)
• Output on/off control using an external contact (CF09: oFF)
• Current setting limit (CF14: on)
• Voltage setting limit (CF15: on)
Displaying the saved contents for confirmation and then recalling
1
Press SHIFT+the memory key (A, B, or C) from which you want to recall
the preset memory entry.
The SET LED and the contents (voltage and current) of the loaded preset memory that
are shown in the display area blink. If you press another memory key, the contents of
the corresponding memory appear blinking.
2
Check the displayed settings, and then press SET.
The SET LED and the LED that corresponds to the loaded preset memory entry both
light, and the set voltage and current are displayed on the panel.
Recalling without displaying the saved contents
1
Use the CONFIG settings to set the PWX series to hide the saved con-
tents of preset memory entries (CF04: oFF).
2
While holding down the SHIFT key, press the appropriate memory key
(A, B, or C).
The LED that corresponds to the preset memory entry that you have loaded (PRESET
A, B, or C) lights.
If no load is connected, it will take time for the output voltage to decrease.
See
If you hold down SHIFT+the memory key (A, B, or C) from which you want to recall the pre-
set memory entry, the present values in use will be saved to the preset memory entry
instead.
See
Memo
This is convenient when
you want to view the
contents that have been
saved to memory.
Memo
Press OCP•OVP,
CONFIG, or PWR DSPL
to cancel the recall
operation.
Memo
This is convenient when
you know the contents
that have been saved to
memory.
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...