SYSTem Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
SYST:CONF:SC1/ SYST:CONF:SC2/ SYST:CONF:SC3
Registers the CONFIG setting item to the panel’s SC key.
Command
SC1 key
SYSTem:CONFigure:SC1 <NRf>
SYSTem:CONFigure:SC1?
SC2 key
SYSTem:CONFigure:SC2 <NRf>
SYSTem:CONFigure:SC2?
SC3 key
SYSTem:CONFigure:SC3 <NRf>
SYSTem:CONFigure:SC3?
Parameter <NRf>
Value:
0
CONFIG parameter content not registered (default)
1 to 99
CF01 to CF99 (invalid if an nonexistent CONFIG parameter
number is specified.
(Example)To register CF40 to the SC1 key
SYST:CONF:SC1 40
Response
Returns the registered CONFIG parameter number in NR3 format in response to
SYST:CONF:SC1?/ SYST:CONF:SC2?/ SYST:CONF:SC3?.
SYST:CONF:SLAV:AMM
Sets whether or not the current or power on slave units is displayed on the panel
during master-slave parallel operation.
Command
SYSTem:CONFigure:SLAVe:AMMeter <boolean>
SYSTem:CONFigure:SLAVe:AMMeter?
Parameter
Value:
ON(1)
Displayed
OFF(0) Not displayed (default)
(Example)
SYST:CONF:SLAV:AMM OFF
Response
Returns whether or not the current or power is displayed on the panel in NR1 for-
mat in response to the SYST:CONF:SLAV:AMM?.