ABORt Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
*WAI
Prevents the PWR-01 from executing subsequent commands until all operations in
standby are complete.
Command
*WAI
ABORt Command
PWR-01 has two different trigger subsystems -TRANsient, and PROGram.
The TRANsient group is a trigger subsystem that changes the output voltage and
current settings.
The PROGram group is used to execute sequences on the PWR-01.
ABOR
Aborts operations such as change and execute sequence in all sequence groups.
The trigger status immediately after the power is turned on is the same as the trig-
ger status when the ABOR command is received.
A specific sequence group cannot be specified with the ABOR command. It is al-
ways interpreted as ALL.
Command
ABORt[:ALL]