Basic Functions | CONFIG Settings
CF22 (
232
)
RS232C interface
Enables or disables the RS232C interface.
Setting this parameter to “
OFF
” disables the RS232C interface function even when an RS232C cable is
connected.
To apply the setting, turn off the power and then turn it back on.
CF23 (
TRAC
)
SCPI communication error display
Sets whether to display communication errors.
When set to “
ON
,” the error is displayed in CH2.
CF24 (
WDOG
)
Communication monitoring (WATCHDOG) timer
Sets the interval for monitoring SCPI command communication
The communication monitoring function operates regardless of whether the product is in remote or local
(panel control) mode.
If you are not using remote control (commands), set this to “
OFF
”.
CF25 (
BEEP
)
Buzzer on or off
Turns the buzzer on and off.
The buzzer sounds when settings are reset to factory defaults, when a communication command error
occurs, or when memory cannot be recalled.
Display
Description
OFF
OFF
RS232C disabled
ON
ON
RS232C enabled (factory default setting).
Display
Description
OFF
OFF
SCPI communication errors are not displayed (factory default set-
ting).
ON
ON
SCPI communication errors are displayed.
Display
Description
OFF
OFF
Communication monitor timer is set to off (factory default setting).
1
to
3000
1 to 3000
1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 1000 s, 3000 s
Display
Description
OFF
OFF
Buzzer off
ON
ON
Buzzer on (factory default setting).