background image

PLZ-5W 1

Checking the Package Contents

Check that all accessories are included and that the unit and 

accessories have not been damaged during transportation. 

If any of the unit and accessories are damaged or missing, 

contact your Kikusui agent or distributor. We recommend that 

you keep all packing materials, in case the product needs to be 

transported at a later date.

Accessories

Rear-panel load 

input terminal 

cover (1 pc.)

Load input terminal 

screw set (2 sets)

[M5-101-008]

[M4-100-008]

[M5-100-008]

[M1-100-119]

Front-panel load 

input terminal 

cover ( 1 pc.)

Front-panel load 

input knob set (1 set)

External control 

connector kit (1 set)

[83-20-0190]

CD-ROM

1 disk

Setup Guide 

(This manual, 1 pc.)

Quick Reference

(Japanese 1 sheet,

 English 1 sheet)

Safety Information (1 pc.)

The attached power cord varies depending on the shipment destination.

Power cord (1 pc., length: 2.5m)

Plug: NEMA5-15

Rating: 125Vac/10A

[85-AA-0004]

Plug: CEE7/7

Rating: 250Vac/10A 

[85-AA-0005]

Plug: GB1002

Rating: 250Vac/10A 

[85-10-0790]

or

or

Cover

[Q1-500-161]

Screw [M8-600-021]

Top [Q1-500-156]

Bottom [Q1-500-157]

+ (red)

[N8-000-003]

 (black)

[N8-000-002]

Screws for the 

load input

terminal cover 

(2 pcs.)

[M3-112-018]

Features

In addition to basic constant current, constant resistance, con-

stant voltage, and constant power modes, the PLZ-5W Series 

offers a variety of other features. The PLZ-5W series also pro-

vides better performance than previous models.
•  High-speed response

The rise time has been improved from 10 µs to 5 µs.

•  Expanded voltage range

The minimum operating voltage has been improved from 

1.5 V to 1.0 V, offering support of low voltage input.

•  Arbitrary I-V characteristics mode

Arbitrary I-V characteristics mode that allows current to be set 

arbitrarily in relation to voltage input. This mode can be used 

for simulation of LED loads and the like.

•  Color liquid crystal display (LCD)

Allows easy-to-see display in color. The voltage value, current 

value, power value, current capacity value (Ah), and power 

capacity value (Wh) at the load input terminal are indicated 

on the display.

•  Increased power capacity and current capacity

Power capacity and current capacity 1.2 times those of 

previous models have been realized while keeping the size 

unchanged.

•  Larger capacity achievable

Larger capacity can be achieved by connecting optional 

boosters (PLZ2405WB) to the PLZ1205W. Up to four booster 

units can be operated in parallel using a PLZ1205W unit as 

the master unit (up to 10.8 kW, 2 160 A).

•  Support of synchronized operation

Load On/off control and the execution of sequences can be 

synchronized for multiple PLZ-5W units.

•  RS232C, USB, and LAN communication functions provided 

as standard

These functions allow easy incorporation into various types of 

inspection systems.

•  GPIB function available as option*

Using the optional GPIB converter (p.126), the GPIB function 

can be used via the RS232C or USB interface.

* Limitation apply to some of the functions.

PART NO. Z1-006-270, IB027762

Mar. 2016

PLZ205W

PLZ405W

PLZ1205W

Setup Guide

ELECTRONIC LOAD PLZ-5W Series

The newest version of the operation manual can be downloaded 

from Download service of Kikusui website.

Website

http://www.kikusui.co.jp/en

KIKUSUI ELECTRONICS CORP.

1-1-3, Higashiyamata, Tsuzuki-ku, Yokohama, 

224-0023, Japan
TEL: +81-45-593-0200 Fax: +81-45-593-7571

Содержание PLZ1205W

Страница 1: ...ved from 1 5 V to 1 0 V offering support of low voltage input Arbitrary I V characteristics mode Arbitrary I V characteristics mode that allows current to be set arbitrarily in relation to voltage inp...

Страница 2: ...e of how to control measuring instruments using a personal computer Quick reference This document briefly explains the control panel and the basic operation of it Safety information This document cont...

Страница 3: ...ge Category II energy consuming equipment that is supplied from a fixed installation 1 Turn the POWER switch off 2 Check that the AC power line meets the nominal input rating of the PLZ 5W The PLZ 5W...

Страница 4: ...nt flows and the voltage at the load input terminals may fall below the minimum operating voltage of the PLZ 5W Using the following table as a reference select wiring whose nominal cross sectional are...

Страница 5: ...her There are two available positions Use the appropriate position for the load cables that you are using For cables up to 10 mm Put the top and bottom load input terminal covers together so that the...

Страница 6: ...erminal on the front panel to the negative polarity of the DUT Connecting the Sensing Cables To perform remote sensing connect the sensing cables A voltage measurement point can be changed from a load...

Страница 7: ...e PLZ 5W remotely by sending commands For details on remote control see the Communication Interface Manual on the included CD ROM The following environment is required to view the Communication Interf...