76
PLZ-4WH
Editing Steps in a Fast Sequence
After you finish configuring the program settings, press NEXT (SHIFT+ ) to configure the
step settings.
You can specify one execution condition (current and trigger output) per step. One step
corresponds to one executed operation in the executed waveform.
The minimum number of steps in a fast sequence is 3. Even if you only specify settings for
step 1 and step 2, when you execute a fast sequence, a step 3 will also be executed.
Editing steps
The number of steps that can be monitored is determined by the RPTSTEP setting (last step)
that you specified when you edited the program.
Configure the following step settings in the monitor screen.
Each time you press
, the cursor moves between items in this order: step number, current,
trigger output setting, and then magnification.
Each time you press
, the cursor moves between items in this order: magnification, trigger
output setting, current, and then step number.
You can use the FILL function to set multiple steps at once.
■
Trigger output (TRIG)
Use this setting to specify whether or not to produce a trigger signal. If you set TRIG to ON,
the TRIG OUT terminal on the front panel produces a trigger signal when the step is
executed.
Item
Setting
Description
STEP
1 to 1024
Step number
Current or conductance
0 to 100 % of the range
The current or conductance that is
produced at the step
Trigger output
_: Off
T: On
The trigger signal during step execution
6.0000
A
STEP:0014
M1
C u r r e n t
S t e p n u m b e r
Tr i g g e r o u t p u t
M a g n i f i c a t i o n
Wa v e f o r m d i s p l a y
Monitor screen
Step n - 1
Step n
TRIG OUT
Example: Set trigger output at step number n
(TRIG ON).
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...