PLZ-4WH
135
Specifications
8
S
p
ecif
ic
at
ions
General specifications
Model
PLZ164WH
PLZ334WH
PLZ1004WH
Input voltage range
100 Vac to 240 Vac (90 Vac to 250 Vac), single phase, continuous
Input frequency range
47 Hz to 63 Hz
Power consumption
80 VAmax
90 VAmax
160 VAmax
Inrush current
1
1
Approx. 70 A when receiving an input of 100 Vac
140 Amax
Protective conductor current
2
2
If the input voltage or input frequency is different, the following equation can be used to calculate the value.
600
μ
A (100 Vac at 50 Hz; TYP)
Operating temperature range
0
°
C to 40
°
C (32
°
F to 104
°
F)
Operating humidity range
20 %rh to 85%rh (no condensation)
Storage temperature range
-20
°
C to 70
°
C (-4
°
F to 158
°
F)
Storage humidity range
90 %rh or less (no condensation)
Isolation voltage
±750 Vdc
Insulation
resistance
Primary to input
terminal
1000 Vdc, 30 M
Ω
or more (ambient humidity of 70 %rh or less)
Primary to chassis
1000 Vdc, 30 M
Ω
or more (ambient humidity of 70 %rh or less)
Secondary to chassis
1000 Vdc, 30 M
Ω
or more (ambient humidity of 70 %rh or less)
Withstand
voltage
Primary to input
terminal
No abnormalities at 1500 Vac for 1 minute
Primary to chassis
No abnormalities at 1500 Vac for 1 minute
Secondary to chassis
No abnormalities at 1 000 Vdc for 1 minute
Dimensions (mm)
See the outline drawing.
Weight
Approx. 7 kg (15.4 lb.)
Approx. 8 kg (17.6 lb.)
Approx. 16 kg (35.3 lb.)
Battery backup
Backs up setup information
Accessories
Power cord
1 pc. (with plug, length: 2.4 m)
Load input terminal
cover
1 pc.
Lockplate for the load
input terminal cover
2 sets
Set of screws for the
load input terminal
2 sets
CD-R
3
3
Contains applications and samples, the User’s Manual, the Communication Interface Manual, and the KI-VISA.
1 pc.
Operation Manual
Setup Guide: 1 pc., Quick Reference(English & Japanese): Each 1 pc.
Electromagnetic compatibility
(EMC)
4
4
Only on models that have CE marking on the panel. Does not apply to specially made or modified PLZ-4WHs.
Complies with the requirements of the following directive and standards.
EMC Directive 2004/108/EC
EN 61326-1
EN 61000-3-2
EN 61000-3-3
Applicable under the Following Condition
The maximum length of all cabling and wiring connected to the PLZ-4WH
must be less than 3 m.
Safety
5
5
This is a Class I product. Be sure to ground this product’s protective conductor terminal. The safety of this
product is only guaranteed when the product is properly grounded.
Complies with the requirements of the following directive and standards.
Low Voltage Directive 2006/95/EC
EN 61010-1
Class I
Pollution degree 2
Input voltage [V] Input frequency [Hz]
Protective conductor current = ×
× 500 [μA]
100 [V]
50 [Hz]
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...