20
PLZ-5W SR Series Setup Guide
Connecting the External Control Device
By connecting the rear-panel EXT CONT connector, front-panel BNC connectors (I MON
OUT connector, TRIG OUT connector) to an external device with signal cables, you can con-
trol and monitor the PLZ-5W SR from the external device (external control).
The BNC connectors are isolated from the chassis and load input terminals.
For details on external control and how to use it, see the PLZ-5W Series User’s Manual.
External control connector kit
To connect the signal cable to the EXT CONT connector, use the included external control
connector kit. For information about how to use this kit, see the TE Connectivity (formerly
AMP) catalog. For information about how to obtain these tools or replacement parts, contact
your Kikusui agent or distributor.
Connecting to the EXT CONT connector
1
Open the load input terminal cover
2
Connect the signal cable to the EXT CONT connector.
3
Adjust the positions of the lock plates for the load input terminal cover
.
4
Close the load input terminal cover
.
5
Connect the signal cable to the external controller.
This completes the external control connection procedure.
Connector model
(on the PLZ-5W SR)
5747461-3 [made by
TE Connectivity
]
Plug model
745211-7 [made by
TE Connectivity
]
Wire diameter
AWG26 to AWG22
Manual pressure welding
tool
Handle assembly 58074-1 [made by
TE Connectivity
]
Head assembly 58063-2 [made by
TE Connectivity
]
Insertion/extraction tool
91232-1 [made by
TE Connectivity
] or equivalent
Run the signal
cable through.