Other Connections
This chapter explains how to connect the PLZ-5W SR to other devices when performing syn-
chronized operation, external control, and remote control.
Connection for Synchronized Operation
You can use the synchronization feature simply by connecting several PLZ-5W SRs or PLZ-
5W series with LAN cables. For details on the synchronization feature, see the PLZ-5W
Series User’s Manual.
You can connect a mixture of various PLZ-5W SR and PLZ-5W series models (for example,
PLZ15005W SR and PLZ1205W). Typical LAN cables (straight) up to 30 m long can be used.
To use LAN cables more than 30 m long, please contact your Kikusui agent or distributor.
1
Turn the POWER switches of all the PLZ-5W SRs and PLZ-5W series
units that you will connect.
2
Open the load input terminal cover
3
Connect a LAN cable to the OUT connector of EXT SYNC.
4
Adjust the positions of the lock plates for the load input terminal cover
.
5
Close the load input terminal cover
.
6
Connect a LAN cable to the IN connector of EXT SYNC on another
device that you want to synchronize with.
For details on connecting to the PLZ-5W series, see the PLZ-5W Series User’s Manual.
For your safety, be sure to attach the SYNC/PARALLEL terminal cover.
WARNING
Risk of electric shock.
• Do not touch the IN/OUT connectors of EXT SYNC while the power is turned ON.
• Do not leave one end of the LAN cable unconnected while the other end is con-
nected to the EXT SYNC connector.
Run the cables