KIKUSUI Electronics Corp.
312
Command processing time
A certain amount of time is required before the commands shown in the following ta-
ble are received by the product.
The processing times shown here are standard values, not guaranteed values.
The processing times vary depending on the settings and the measurement condi-
tions.
The values shown below do not include hardware response times.
Command
GPIB
*1
processing
time (ms)
USB
processing
time (ms)
RS232C
*2
processing
time (ms)
LAN
*3
processing
time (ms)
Description
VOLT
7
7
5
6
Sets the voltage
MEAS:VOLT? 111
110
100
120
Queries the
measured output
voltage
FREQ
6
6
6
6
Sets the frequen-
cy
MEAS:CURR? 111
110
100
120
Queries the
measured output
current
*RST
600
500
500
520
Resets the device
*1
: Using a USB-GPIB by National Instruments
*2
: Baud rate setting: 19200bps
*3
: 100BASE-TX Ethernet