PROG:EDIT:PHAS:UOFF
Sets the U phase offset phase angle of a sequence step.
Use PROG:EDIT:PHAS:RAMP to set the phase signal change.
This command is valid for three-phase output.
Command
PROGram:EDIT:PHASe:UOFFset <step_NRf>,<enable_boolean>,<phase_NR3>
PROGram:EDIT:PHASe:UOFFset? <step_NRf>
Parameter
<step_NRf>
Value: 1 to 599 Number of the step that you want to configure
Parameter
<enable_boolean>
Value:
ON(1)
Enables U phase offset
OFF(0) Disables the U phase offset (default)
Parameter
<phase_NR3>
Value:
-360.00 to 360.00 U phase offset value (The default value is 0)
Unit:
DEG
Example
PROG:EDIT:PHAS:UOFF 1,ON,90
Response
Returns the U phase offset value of the specified step in the following order.
U phase offset enabled/disabled<NR1>, U phase offset value<NR3>