PROGram Command
PCR-WE Interface Manual
125
PROG:EDIT:PHAS:RAMP
Sets the phase signal change of a sequence step.
Set the U phase angle with the U phase offset (PROG:EDIT:PHAS:UOFF).
Set the V phase angle with the U-V phase difference (PROG:EDIT:PHAS:UV).
Set the W phase angle with the U-W phase difference (PROG:EDIT:PHAS:UW).
This command is valid for three-phase output.
Command
PROGram:EDIT:PHASe:RAMP <step_NRf>,<u-phase_character>[,<v-phase_
character>[,<w-phase_character>]]
PROGram:EDIT:PHASe:RAMP? <step_NRf>
Parameter
<step_NRf>
Value: 0 to 599 Number of the step that you want to configure
Parameter
<u-phase_character> U phase signal change, <v-phase_character> V
phase signal change, <w-phase_character> W phase signal change
Value:
OFF
Ramp off (default)
LEAD
Ramp on, leading
LAG
Ramp on, lagging
Example
PROG:EDIT:PHAS:RAMP 1,LAG,OFF,OFF
PROG:EDIT:PHAS:RAMP? 1
Response
Returns the phase signal change settings of the specified step in the following or-
der.
U phase signal change<characters>, V phase signal change<characters>, W
phase signal change<characters>