PROGram Command
PCR-WE Interface Manual
123
PROG:EDIT:IMP:REAC
Sets the reactance component of the output impedance used in the sequence step.
This command is valid when the output impedance (PROG:EDIT:IMP) of the se-
quence is to be set.
Command
PROGram:EDIT:IMPerdance:REACtive <step_NRf>,<reac_NRf>[,@chanlist]
PROGram:EDIT:IMPerdance:REACtive? <step_NRf>[,(@chanlist)]
Parameter
<step_NRf>
Value: 0 to 599 Number of the step that you want to configure
Parameter
<reac_NRf>
Value: Reactance component (The default value is 0.)
L range
H range
Single-phase
Single-phase
three-wire,
Three phase
Single-phase
Single-phase
three-wire,
Three phase
PCR1000WE
80 µH to 2000 µH --
320 µH to 8000 µH --
PCR2000WE
40 µH to 1000 µH --
160 µH to 4000 µH --
PCR3000WE2 27 µH to 667 µH 80 µH to 2000 µH 107 µH to 2667 µH 320 µH to 8000 µH
PCR6000WE2 13 µH to 333 µH 40 µH to 1000 µH 53 µH to 1333 µH 160 µH to 4000 µH
PCR12000WE2 7 µH to 167 µH
20 µH to 500 µH 27 µH to 667 µH
80 µH to 2000 µH
PCR18000WE2 4 µH to 111 µH
13 µH to 333 µH 18 µH to 444 µH
53 µH to 1333 µH
PCR24000WE2 3 µH to 83 µH
10 µH to 250 µH 13 µH to 333 µH
40 µH to 1000 µH
PCR30000WE2 3 µH to 67 µH
8 µH to 200 µH
11 µH to 267 µH
32 µH to 800 µH
PCR36000WE2 2 µH to 56 µH
7 µH to 167 µH
9 µH to 222 µH
27 µH to 667 µH
Unit: H
Example
PROG:EDIT:IMP:REAC 1,1UH
Response: NR3