KIKUSUI Electronics Corp.
120
PROG:EDIT:FUNC:BANK
Sets the waveform bank number of the sequence step.
Command
PROGram:EDIT:FUNCtion[:SHAPe]:BANK[:INDex] <step_NRf>,<bank_NRf>[,@
chanlist]
PROGram:EDIT:FUNCtion[:SHAPe]:BANK[:INDex]? <step_NRf>[,@chanlist]
Parameter
<step_NRf>
Value: 0 to 599 Number of the step that you want to configure
Parameter
<bank_NRf>
Value: 0 to 256 Number of the waveform bank to use (The default value is 0)
Example
PROG:EDIT:FUNC:BANK 1,256
Response
Returns the waveform bank number of the designated step in NR1 format in response
to PROG:EDIT:FUNC:BANK? <step_NRf>.