A-20
PAT-T 4kW
Output on/off delay function (Sequence 2: OUTPut)
The TRIGger:SEQuence2 (or TRIGger:OUTPut) subsystem allows you to use the
output on/off delay function. To reserve the operation of the output change using
triggers, use the OUTPut:TRIGgered command.
:TRIGger:SEQuence2:SOURce BUS
'
Set the trigger so
u
rce to BUS
:TRIGger:SEQuence2:DELay:ON 0.5
'
Set the o
u
tp
u
t on delay to 0.5 s
:OUTPut:TRIGgered ON
'
Set the o
u
tp
u
t to be t
u
rned on
'
w
hen a trigger is applied
:INITiate:SEQuence2
'
Initiate seq
u
ence 2
:TRIGger:SEQuence2
'
Apply a soft
w
are trigger to seq
u
ence 2
The TRIGger:SEQuence2:SOURce command sets the trigger source (BUS or
IMMediate). The :TRIGger:SEQuence2:DELay:ON command sets the delay for
turning on the output after the trigger is applied. If this value is set to 0, the output is
turned on without delay. Though not used in the example above,
the:TRIGger:SEQuence2:DELay:OFF command sets the delay for turning off the
output after the trigger is applied.
The INITiate:IMMediate:SEQuence2 command makes the trigger subsystem leave
the IDLE state and go the initiated state. If the trigger source is set to IMMediate,
the output on/off delay starts immediately. If the trigger source is set to BUS, the
trigger subsystem moves to the WTG (Waiting For Trigger) state. When a software
trigger is applied with the TRIGger:SEQuence2 or *TRG common command, the
delay action is executed. When the operation is completed, the trigger subsystem
returns to the IDLE state again. If an ABORt or an equivalent command is sent
without executing the trigger, the delay action is cancelled, and then the trigger
subsystem returns to the IDLE state.
If the on or off state specified with the OUTPut:TRIGgered command is the same as
the present output state, the SEQuence2 (OUTPut) trigger subsystem completes the
apparent action immediately, because there is no actual action that needs to be
taken. No error is generated in this case.
If the delay action in progress is aborted by sending an abort command, Device
Clear (GPIB/USB), or break signal (RS232), the output state returns to the state that
existed before the delay action was executed. Likewise, the *RST command also
aborts the operation, but the output state is always set to off.
If the output state is set by force with an OUTPut command while the delay action is
in progress, the delay action is aborted, and the output is set to the state specified by
the OUTPut command.
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...