PAT-T 4kW
A-17
Appx
A.6.2
Output Programming
Voltage and current
The output voltage and output current are controlled by the VOLTage and CURRent
commands. The output ON/OFF state is controlled by the OUTPut command.
:VOLTage 13.5
' Set the voltage to 13.5 V
:CURRent 4.5
' Set the c
u
rrent to 4.5 A
:OUTPut ON
' T
u
rn the o
u
tp
u
t on
To set the preset current to the maximum value, set the value of the CURRent
command to MAXimum.
The current setting limit is set to approximately 95 % of the value specified by the
CURRent:PROTection command if the CURRent:LIMit:AUTO command is set to
ON (1). The setting limit cannot be set above this value. If the
CURRent:LIMit:AUTO command is set to OFF (0), the setting limit is the
maximum value of preset range (105 % of the rated output current).
:VOLTage 13.5
' Set the voltage to 13.5 V
:CURRent MAXimum
' Set the c
u
rrent to the max.val
u
e
To set the preset voltage to the maximum value, set the value of the VOLTage
command to MAXimum.
The voltage limit setting is set to approximately 95 % of the value specified by the
VOLTage:PROTection command if the VOLTage:LIMit:AUTO command is set to
ON (1). The setting limit cannot be set above this value. If the
VOLTage:LIMit:AUTO command is set to OFF (0), the setting limit is the
maximum value of preset range (105 % of the rated output voltage).
:CURRent 4.5
' Set the c
u
rrent to 4.5 A
:VOLTage MAXimum
' Set the voltage to the max.val
u
e
You can confirm the maximum allowed value that can be specified in the VOLTage
and CURRent commands by specifying the MAXimum parameter in the VOLTage?
and CURRent? queries, respectively.
:VOLTage? MAXimum
←
Read the response
:CURRent? MAXimum
←
Read the response
The values that the queries above return may vary depending on the
VOLTage:PROTection (OVP) and CURRent:PROTection (OCP) settings.
If a value exceeding the upper limit is specified with the VOLTage or CURRent
command, it is interpreted as MAXimum and does not result in an error.
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...