7-26
PAT-T 4KW
Operation when a protection function is activated
SYST:CONF:BTR:PROT
Sets whether to trip the breaker (turn the POWER switch off) when the overvoltage
protection (OVP) or overcurrent protection (OCP) is activated.
Command
SYSTem:CONFigure:BTRip:PROTection {ON|OFF|1|0}
SYSTem:CONFigure:BTRip:PROTection?
Parameter
Val
u
e:
ON(1)
Trip (turn the POWER switch off)
OFF(0)
Not trip (turn the output off) (default)
Response
Returns whether to trip the breaker when the OVP or OCP is activated in the NR1
form in response to SYST:CONF:BTR:PROT?.
SYST:CONF:BTR:SHUT
Sets whether to trip the breaker (turn the POWER switch off) when an external
shutdown (SD) signal is applied.
Command
SYSTem:CONFigure:BTRip:SHUTdown {ON|OFF|1|0}
SYSTem:CONFigure:BTRip:SHUTdown?
Parameter
Val
u
e:
ON(1)
Trip (turn the POWER switch off)
OFF(0)
Not trip (turn the output off) (default)
Response
Returns whether to trip the breaker when the SD signal is applied in the NR1 form
in response to SYST:CONF:BTR:SHUT?.
7.11 Releasing the Alarm
OUTP:PROT:CLE
Clears the alarm, except for the “Fan failure protection (FAN)”.
The alarm resumes even clearing the alarm by sending this command unless the
cause of alarm to be solved.
Command
OUTPut:PROTection:CLEar
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...