PAD-L
Names and Functions of Controls
5-5
10 VOLTAGE setting knob
This is used to set output voltage for constant voltage operation mode. (10 turns)
11 C.V lamp
This is displayed when the unit is in its constant voltage operation mode.
12 A.
FS
variable resistor
This is used to adjust the ammeter. For information on performing adjustments, see
6.3.4 "Adjustment procedure".
13 V.
FS
variable resistor
This is used to adjust the voltmeter. For information on performing adjustments, see
6.3.4 "Adjustment procedure".
14 I.
OS
variable resistor
This is used to adjust the output current offset resulting when the CURRENT setting
knob is turned to the extreme counterclockwise position. It is also used to adjust
input offset voltage for "Output current control with an external voltage", as in 4.4.2.
15 V.
OS
variable resistor
This is used to adjust the output voltage offset resulting when the VOLTAGE setting
knob is turned to the extreme counterclockwise position. It is also used to adjust the
input offset voltage for "Output voltage control with an external voltage", as in 4.2.3.
16 O.V.P variable resistor
This is used to set the OVP (overvoltage protection) trip point.
If the output voltage exceeds a set value due to inadvertent operation or failure, this
function shuts off the POWER switch to protect the load. For information on
performing this setting, see 3.2.1 "OVP (overvoltage protection) trip point
presetting".
17 VOLTAGE CHECK terminals
These terminals are used to check the output voltage from the front panel by
connecting a digital voltmeter (DVM). The unit incorporates a 0.1 A output fuse to
guard against short-circuiting of these terminals.
The voltage check chips supplied are used to connect an external DVM.
18 Casters
The casters on the front panel side of the TYPE IV and TYPE V models are provided
with a locking mechanism. For information on locking the casters, see 1.2
"Installation".
19 Stopper bolts (TYPE III and TYPE V models only)
These are used to lock the unit at an installation site. For information on locking the
unit, see 1.2 Installation.
The TYPE IV models do not have stopper bolts.
20 O.V.P PRESET switch (TYPE V models only)
The voltmeter indicates the OVP set value when this switch is held down.
This switch is not provided for TYPE III and TYPE IV models.
Содержание PAD-L III Series
Страница 4: ...II PAD L...
Страница 16: ...P 6 Preface PAD L...
Страница 17: ...1 1 PAD L Setup 1 1 Chapter 1 Setup Describes the necessary procedure from unpacking to preparation before use...
Страница 40: ...2 12 Precautions and Preparations for Use PAD L...
Страница 86: ...4 34 Applied Operation PAD L...
Страница 93: ...PAD L Names and Functions of Controls 5 7 22 25 23 26 24 21 Fig 5 6 PAD L series PAD250 15L rear panel...
Страница 95: ...PAD L Names and Functions of Controls 5 9 22 26 23 25 21 24 28 29 Fig 5 8 PAD L series PAD110 60L rear panel...
Страница 98: ...5 12 Names and Functions of Controls PAD L...
Страница 130: ...7 14 Specifications PAD L...